Eaton HC7-1R0-R 1.05 uH High-Current Inductor 2.1 mOhm
Eaton HC7-1R0-R 1.05 uH High-Current Inductor 2.1 mOhm

Eaton HC7-1R0-R 1.05 uH High-Current Inductor 2.1 mOhm

Share
Eaton HC7-1R0-R: powder iron high-current inductor, 1.05 uH ±20%, 20.3 A Irms, Isat 19.6 A, DCR 2.1 mOhm, 13.8 mm long.
    • Product Details
    • Download

    Eaton HC7-1R0-R 1.05 uH High-Current Inductor 2.1 mOhm

    HC7-1R0-R at a glance: powder iron high-current inductor, 1.05 uH ±20%, 20.3 A Irms, Isat 19.6 A (15% rolloff), DCR 2.1 mOhm, 13.8 mm long.

    Electrical Specifications

    ParameterValue
    Orderable part numberHC7-1R0-R
    OCL (open circuit inductance)1.05 uH ±20%
    Irms (DC, 40 °C rise)20.3 A
    Isat (15% rolloff)19.6 A
    Isat2 (30% rolloff)37.1 A
    DCR typical @ +20 °C2.1 mOhm
    Volt-time rating (V-us)5.36
    Package13.8 mm long
    Height5.5 mm
    MountingSurface mount
    Operating temperature-40 °C to +155 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4116

    Dimensions and Pad Layout

    HC7-1R0-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4116: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    The Figures Explained

    A powder core with a non-organic binder is a deliberately conservative choice: it trades a little permeability for predictable behaviour at high current and high temperature. The result is an inductor that stays linear enough for a current-mode loop to be designed around it.

    Copper loss at the rated current works out to roughly 0.865 W from a typical DCR of 2.1 mOhm at 20.3 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.

    Isat is specified as 15% rolloff, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.

    Energy storage at the saturation current is around 202 uJ, the number that connects the inductance and the current rating into a single transient figure.

    The second saturation column, 37.1 A at 30% rolloff, is the same core taken further into rolloff. The ratio between the two columns is a direct measure of how soft the curve is: a part with a wide gap between them loses inductance slowly and tolerates a larger transient peak.

    Where This Series Fits

    The HC powder family sits at the higher-inductance end of the high-current range: from a fraction of a microhenry up to tens of microhenry, on surface-mount bodies with powder iron cores. Every row carries two saturation columns so the rolloff criterion can be chosen explicitly.

    The HC7 family spans 0.22 uH to 4.81 uH; this row sits at position 3 of 7.

    The next value up in the same family, HC7-1R5-R, gives 1.73 uH at 14.2 A and DCR 4.3 mOhm: the extra inductance costs about 9.2 A of rated current.

    • Core material: powder iron core, 13.8 mm long body at 5.5 mm.
    • Typical applications: multi-phase regulators; voltage regulator modules (vrms); distributed power systems dc-dc converters; desktop and server vrms and evrds; point-of-load (pol) modules; field programmable gate array (fpga) dc-dc converters.
    • The two saturation columns are different criteria, not two measurements of the same thing. Pick the rolloff you can tolerate in the application and stay with that column.

    Sizing and Layout Notes

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 2.1 mOhm becomes roughly 3.21 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: use the 30% rolloff column only if the loop can tolerate the inductance droop; the tighter column keeps more inductance at the cost of a lower usable peak current.

    • Confirm the part marking is visible after placement for traceability.
    • Check that the inductance at the working DC bias still meets the ripple target.
    • Confirm the part marking is visible after placement for traceability.

    Frequently Asked Questions

    How do I estimate the inductance at my operating current?
    Read it off the inductance-versus-DC-bias curve in the data sheet at the actual bias. The curve, not the OCL value, is what sets the ripple at load.

    Does the inductance drift with age?
    The binder is non-organic and the core is not gapped with adhesive, so thermal aging of the magnetic path is not a mechanism here. The value is stable across thermal cycles.

    Why is the DCR higher than a ferrite part of the same size?
    Iron powder has lower permeability, so more turns are needed for the same inductance, and more turns mean more copper. The compensation is the much higher saturation flux density.