Eaton HC7-2R2-R 2.58 uH SMD Power Inductor, 8.4 V-us
Eaton HC7-2R2-R 2.58 uH SMD Power Inductor, 8.4 V-us

Eaton HC7-2R2-R 2.58 uH SMD Power Inductor, 8.4 V-us

Share
Eaton HC7-2R2-R: powder iron high-current inductor, 2.58 uH ±20%, 13 A Irms, Isat 12.5 A, DCR 5.2 mOhm, 13.8 mm long.
    • Product Details
    • Download

    Eaton HC7-2R2-R 2.58 uH SMD Power Inductor, 8.4 V-us

    HC7-2R2-R at a glance: powder iron high-current inductor, 2.58 uH ±20%, 13 A Irms, Isat 12.5 A (15% rolloff), DCR 5.2 mOhm, 13.8 mm long.

    Key Specifications

    ParameterValue
    Orderable part numberHC7-2R2-R
    OCL (open circuit inductance)2.58 uH ±20%
    Irms (DC, 40 °C rise)13 A
    Isat (15% rolloff)12.5 A
    Isat2 (30% rolloff)23.6 A
    DCR typical @ +20 °C5.2 mOhm
    Volt-time rating (V-us)8.4
    Package13.8 mm long
    Height5.5 mm
    MountingSurface mount
    Operating temperature-40 °C to +155 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4116

    Outline Drawing

    HC7-2R2-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4116: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    The Figures Explained

    A powder core with a non-organic binder is a deliberately conservative choice: it trades a little permeability for predictable behaviour at high current and high temperature. The result is an inductor that stays linear enough for a current-mode loop to be designed around it.

    With 5.2 mOhm typical, the I-squared-R loss at the full 13 A rating is about 0.879 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.

    The Isat column is 15% rolloff. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.

    At Isat the part holds about 202 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.

    The second saturation column, 23.6 A at 30% rolloff, is the same core taken further into rolloff. The ratio between the two columns is a direct measure of how soft the curve is: a part with a wide gap between them loses inductance slowly and tolerates a larger transient peak.

    Positioning in the Range

    The HC powder family sits at the higher-inductance end of the high-current range: from a fraction of a microhenry up to tens of microhenry, on surface-mount bodies with powder iron cores. Every row carries two saturation columns so the rolloff criterion can be chosen explicitly.

    In the HC7 line-up this part is number 5 of 7 by inductance, between 0.22 uH and 4.81 uH.

    The next value up in the same family, HC7-3R9-R, gives 3.61 uH at 10.4 A and DCR 7.9 mOhm: the extra inductance costs about 3.8 A of rated current.

    • Core material: powder iron core, 13.8 mm long body at 5.5 mm.
    • Typical applications: multi-phase regulators; voltage regulator modules (vrms); distributed power systems dc-dc converters; desktop and server vrms and evrds; point-of-load (pol) modules; field programmable gate array (fpga) dc-dc converters.
    • The two saturation columns are different criteria, not two measurements of the same thing. Pick the rolloff you can tolerate in the application and stay with that column.

    Sizing It Into a Design

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 5.2 mOhm becomes roughly 7.96 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: use the 30% rolloff column only if the loop can tolerate the inductance droop; the tighter column keeps more inductance at the cost of a lower usable peak current.

    • Compare the two saturation columns before fixing the current limit in the controller.
    • Check that the inductance at the working DC bias still meets the ripple target.
    • Check that the inductance at the working DC bias still meets the ripple target.

    Frequently Asked Questions

    How do I estimate the inductance at my operating current?
    Read it off the inductance-versus-DC-bias curve in the data sheet at the actual bias. The curve, not the OCL value, is what sets the ripple at load.

    Why is the DCR higher than a ferrite part of the same size?
    Iron powder has lower permeability, so more turns are needed for the same inductance, and more turns mean more copper. The compensation is the much higher saturation flux density.

    Why is the DCR higher than a ferrite part of the same size?
    Iron powder has lower permeability, so more turns are needed for the same inductance, and more turns mean more copper. The compensation is the much higher saturation flux density.

    Shenzhen Gaorunxin Technology Co., Ltd