Eaton HC8-100-R 9.77 uH Powder Iron Inductor, 5.2 A
Eaton HC8-100-R 9.77 uH Powder Iron Inductor, 5.2 A

Eaton HC8-100-R 9.77 uH Powder Iron Inductor, 5.2 A

Share
Eaton HC8-100-R: powder iron high-current inductor, 9.77 uH ±20%, 5.2 A Irms, Isat 5.2 A, DCR 43.6 mOhm, 10.9 x 10.4 mm.
    • Product Details
    • Download

    Eaton HC8-100-R 9.77 uH Powder Iron Inductor, 5.2 A

    HC8-100-R at a glance: powder iron high-current inductor, 9.77 uH ±20%, 5.2 A Irms, Isat 5.2 A (15% rolloff), DCR 43.6 mOhm, 10.9 x 10.4 mm.

    Specification Table

    ParameterValue
    Orderable part numberHC8-100-R
    OCL (open circuit inductance)9.77 uH ±20%
    Irms (DC, 40 °C rise)5.2 A
    Isat (15% rolloff)5.2 A
    Isat2 (30% rolloff)9.2 A
    DCR typical @ +20 °C43.6 mOhm
    Volt-time rating (V-us)12.5
    Package10.9 x 10.4 mm
    Height4.0 mm
    MountingSurface mount
    Operating temperature-40 °C to +155 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4120

    Dimensions and Pad Layout

    HC8-100-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4120: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    The Figures Explained

    A powder core with a non-organic binder is a deliberately conservative choice: it trades a little permeability for predictable behaviour at high current and high temperature. The result is an inductor that stays linear enough for a current-mode loop to be designed around it.

    Copper loss at the rated current works out to roughly 1.18 W from a typical DCR of 43.6 mOhm at 5.2 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.

    Isat is specified as 15% rolloff, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.

    Energy storage at the saturation current is around 132 uJ, the number that connects the inductance and the current rating into a single transient figure.

    The second saturation column, 9.2 A at 30% rolloff, is the same core taken further into rolloff. The ratio between the two columns is a direct measure of how soft the curve is: a part with a wide gap between them loses inductance slowly and tolerates a larger transient peak.

    Where This Series Fits

    The HC powder family sits at the higher-inductance end of the high-current range: from a fraction of a microhenry up to tens of microhenry, on surface-mount bodies with powder iron cores. Every row carries two saturation columns so the rolloff criterion can be chosen explicitly.

    In the HC8 line-up this part is number 12 of 16 by inductance, between 0.175 uH and 47.3 uH.

    One step down the table, HC8-8R2-R, sits at 8.27 uH with 5.5 A and 39.6 mOhm – the lower inductance buys about 1.4 A of extra current in the same body.

    • Core material: powder iron core, 10.9 x 10.4 mm body at 4.0 mm.
    • Typical applications: multi-phase regulators; voltage regulator modules (vrms); distributed power systems dc-dc converters; desktop and server vrms and evrds; point-of-load (pol) modules; field programmable gate array (fpga) dc-dc converters.
    • The two saturation columns are different criteria, not two measurements of the same thing. Pick the rolloff you can tolerate in the application and stay with that column.

    Sizing and Layout Notes

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 43.6 mOhm becomes roughly 66.7 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: use the 30% rolloff column only if the loop can tolerate the inductance droop; the tighter column keeps more inductance at the cost of a lower usable peak current.

    • Check that the inductance at the working DC bias still meets the ripple target.
    • Check that the inductance at the working DC bias still meets the ripple target.
    • Use the inductance-versus-DC-bias curve for the ripple calculation, not OCL.

    Frequently Asked Questions

    Is the part shielded?
    The winding is enclosed by the powder core, so the external field is small. It is not a closed ferrite shield, but the fringing field is low enough for dense board layouts.

    What is soft saturation?
    The inductance falls gradually as current rises instead of collapsing at a threshold. A powder core with a distributed gap behaves this way, which keeps the converter stable through a load transient.

    Is the part shielded?
    The winding is enclosed by the powder core, so the external field is small. It is not a closed ferrite shield, but the fringing field is low enough for dense board layouts.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products