Eaton HC8-150-R: powder iron high-current inductor, 15.02 uH ±20%, 4.1 A Irms, Isat 4.2 A, DCR 68.6 mOhm, 10.9 x 10.4 mm.
    • Product Details
    • Download

    Eaton HC8-150-R 15.02 uH SMD Power Inductor, 15.5 V-us

    HC8-150-R at a glance: powder iron high-current inductor, 15.02 uH ±20%, 4.1 A Irms, Isat 4.2 A (15% rolloff), DCR 68.6 mOhm, 10.9 x 10.4 mm.

    Specification Table

    ParameterValue
    Orderable part numberHC8-150-R
    OCL (open circuit inductance)15.02 uH ±20%
    Irms (DC, 40 °C rise)4.1 A
    Isat (15% rolloff)4.2 A
    Isat2 (30% rolloff)7.4 A
    DCR typical @ +20 °C68.6 mOhm
    Volt-time rating (V-us)15.5
    Package10.9 x 10.4 mm
    Height4.0 mm
    MountingSurface mount
    Operating temperature-40 °C to +155 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4120

    Outline Drawing

    HC8-150-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4120: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    Reading the Data Sheet

    This is a surface-mount inductor on a distributed air gap: the powder core spreads the gap through the whole volume, which is why the part tolerates large DC bias without a cliff in the inductance curve, and why it is used on multiphase rails where the inductors share current.

    The DCR figure of 68.6 mOhm is what sets the efficiency: at 4.1 A the winding drops about 0.281 mV and dissipates 1.15 W. On a low-voltage rail that drop is a measurable fraction of the output, so the DCR column deserves as much attention as the inductance.

    The saturation rating reads 15% rolloff. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.

    At Isat the part holds about 132 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.

    The second saturation column, 7.4 A at 30% rolloff, is the same core taken further into rolloff. The ratio between the two columns is a direct measure of how soft the curve is: a part with a wide gap between them loses inductance slowly and tolerates a larger transient peak.

    Positioning in the Range

    The HC powder family sits at the higher-inductance end of the high-current range: from a fraction of a microhenry up to tens of microhenry, on surface-mount bodies with powder iron cores. Every row carries two saturation columns so the rolloff criterion can be chosen explicitly.

    The HC8 family spans 0.175 uH to 47.3 uH; this row sits at position 13 of 16.

    One step down the table, HC8-100-R, sits at 9.77 uH with 5.2 A and 43.6 mOhm – the lower inductance buys about 1.8 A of extra current in the same body.

    • Core material: powder iron core, 10.9 x 10.4 mm body at 4.0 mm.
    • Typical applications: multi-phase regulators; voltage regulator modules (vrms); distributed power systems dc-dc converters; desktop and server vrms and evrds; point-of-load (pol) modules; field programmable gate array (fpga) dc-dc converters.
    • The two saturation columns are different criteria, not two measurements of the same thing. Pick the rolloff you can tolerate in the application and stay with that column.

    Design Notes

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 68.6 mOhm becomes roughly 105 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: use the 30% rolloff column only if the loop can tolerate the inductance droop; the tighter column keeps more inductance at the cost of a lower usable peak current.

    • Check the volt-time rating against the applied V-us at the switching frequency.
    • Check the volt-time rating against the applied V-us at the switching frequency.
    • Use the inductance-versus-DC-bias curve for the ripple calculation, not OCL.

    Frequently Asked Questions

    Which saturation column should I design to?
    The one that matches the inductance droop your loop can tolerate. The 30 % column gives a higher usable peak current; the tighter column keeps more inductance at the cost of headroom.

    Why is the DCR higher than a ferrite part of the same size?
    Iron powder has lower permeability, so more turns are needed for the same inductance, and more turns mean more copper. The compensation is the much higher saturation flux density.

    Which saturation column should I design to?
    The one that matches the inductance droop your loop can tolerate. The 30 % column gives a higher usable peak current; the tighter column keeps more inductance at the cost of headroom.