Eaton HC8-1R2-R 1.32 uH Powder Iron Inductor, 16 A
Eaton HC8-1R2-R 1.32 uH Powder Iron Inductor, 16 A

Eaton HC8-1R2-R 1.32 uH Powder Iron Inductor, 16 A

Share
Eaton HC8-1R2-R: powder iron high-current inductor, 1.32 uH ±20%, 16 A Irms, Isat 14.4 A, DCR 4.7 mOhm, 10.9 x 10.4 mm.
    • Product Details
    • Download

    Eaton HC8-1R2-R 1.32 uH Powder Iron Inductor, 16 A

    HC8-1R2-R at a glance: powder iron high-current inductor, 1.32 uH ±20%, 16 A Irms, Isat 14.4 A (15% rolloff), DCR 4.7 mOhm, 10.9 x 10.4 mm.

    Key Specifications

    ParameterValue
    Orderable part numberHC8-1R2-R
    OCL (open circuit inductance)1.32 uH ±20%
    Irms (DC, 40 °C rise)16 A
    Isat (15% rolloff)14.4 A
    Isat2 (30% rolloff)25.5 A
    DCR typical @ +20 °C4.7 mOhm
    Volt-time rating (V-us)4.5
    Package10.9 x 10.4 mm
    Height4.0 mm
    MountingSurface mount
    Operating temperature-40 °C to +155 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4120

    Mechanical Drawing

    HC8-1R2-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4120: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    The Figures Explained

    A powder core with a non-organic binder is a deliberately conservative choice: it trades a little permeability for predictable behaviour at high current and high temperature. The result is an inductor that stays linear enough for a current-mode loop to be designed around it.

    Copper loss at the rated current works out to roughly 1.2 W from a typical DCR of 4.7 mOhm at 16 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.

    Saturation is quoted as 15% rolloff. At that point the inductance has fallen to the stated fraction of its nominal value – the part is not damaged there, it simply stops behaving like the inductance on the label. Design the peak current to stay inside that boundary with margin for tolerance.

    The core stores roughly 137 uJ at the saturation point – a useful figure when sizing the output capacitance that has to absorb the same transient.

    The second saturation column, 25.5 A at 30% rolloff, is the same core taken further into rolloff. The ratio between the two columns is a direct measure of how soft the curve is: a part with a wide gap between them loses inductance slowly and tolerates a larger transient peak.

    Where This Series Fits

    The HC powder family sits at the higher-inductance end of the high-current range: from a fraction of a microhenry up to tens of microhenry, on surface-mount bodies with powder iron cores. Every row carries two saturation columns so the rolloff criterion can be chosen explicitly.

    In the HC8 line-up this part is number 4 of 16 by inductance, between 0.175 uH and 47.3 uH.

    One step down the table, HC8-R75-R, sits at 0.766 uH with 18.8 A and 3.4 mOhm – the lower inductance buys about 6.4 A of extra current in the same body.

    • Core material: powder iron core, 10.9 x 10.4 mm body at 4.0 mm.
    • Typical applications: multi-phase regulators; voltage regulator modules (vrms); distributed power systems dc-dc converters; desktop and server vrms and evrds; point-of-load (pol) modules; field programmable gate array (fpga) dc-dc converters.
    • The two saturation columns are different criteria, not two measurements of the same thing. Pick the rolloff you can tolerate in the application and stay with that column.

    Putting It to Work

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 4.7 mOhm becomes roughly 7.19 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: use the 30% rolloff column only if the loop can tolerate the inductance droop; the tighter column keeps more inductance at the cost of a lower usable peak current.

    • Confirm the part marking is visible after placement for traceability.
    • Decide which rolloff column the loop can tolerate, then stay with that column.
    • Check the volt-time rating against the applied V-us at the switching frequency.

    Frequently Asked Questions

    How do I estimate the inductance at my operating current?
    Read it off the inductance-versus-DC-bias curve in the data sheet at the actual bias. The curve, not the OCL value, is what sets the ripple at load.

    Does the inductance drift with age?
    The binder is non-organic and the core is not gapped with adhesive, so thermal aging of the magnetic path is not a mechanism here. The value is stable across thermal cycles.

    What is soft saturation?
    The inductance falls gradually as current rises instead of collapsing at a threshold. A powder core with a distributed gap behaves this way, which keeps the converter stable through a load transient.