Eaton HC8LP-5R6-R 5.71 uH SMD Power Inductor, 7.1 V-us
Eaton HC8LP-5R6-R 5.71 uH SMD Power Inductor, 7.1 V-us

Eaton HC8LP-5R6-R 5.71 uH SMD Power Inductor, 7.1 V-us

Share
Eaton HC8LP-5R6-R: powder iron high-current inductor, 5.71 uH ±20%, 5.5 A Irms, Isat 5.1 A, DCR 38.9 mOhm, 10.9 x 10.4 mm.
    • Product Details
    • Download

    Eaton HC8LP-5R6-R 5.71 uH SMD Power Inductor, 7.1 V-us

    HC8LP-5R6-R at a glance: powder iron high-current inductor, 5.71 uH ±20%, 5.5 A Irms, Isat 5.1 A (15% rolloff), DCR 38.9 mOhm, 10.9 x 10.4 mm.

    Ratings at a Glance

    ParameterValue
    Orderable part numberHC8LP-5R6-R
    OCL (open circuit inductance)5.71 uH ±20%
    Irms (DC, 40 °C rise)5.5 A
    Isat (15% rolloff)5.1 A
    Isat2 (30% rolloff)9 A
    DCR typical @ +20 °C38.9 mOhm
    Volt-time rating (V-us)7.1
    Package10.9 x 10.4 mm
    Height3.5 mm
    MountingSurface mount
    Operating temperature-40 °C to +155 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4126

    Dimensions and Pad Layout

    HC8LP-5R6-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4126: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    What the Numbers Mean

    The core is iron powder held in a high-temperature non-organic binder. That construction does not saturate abruptly: as current rises the permeability falls progressively, so the inductance droops instead of collapsing. For a switching regulator working near its current limit during a transient, that behaviour keeps the control loop in a known place.

    At the rated 5.5 A the winding dissipates about 1.18 W in copper alone, using the typical DCR of 38.9 mOhm. That figure is the floor of the loss budget: it assumes the current is pure DC, and any ripple adds to it.

    The Isat column is 15% rolloff. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.

    Energy storage at the saturation current is around 74.3 uJ, the number that connects the inductance and the current rating into a single transient figure.

    The second saturation column, 9 A at 30% rolloff, is the same core taken further into rolloff. The ratio between the two columns is a direct measure of how soft the curve is: a part with a wide gap between them loses inductance slowly and tolerates a larger transient peak.

    What This Family Is For

    The HC powder family sits at the higher-inductance end of the high-current range: from a fraction of a microhenry up to tens of microhenry, on surface-mount bodies with powder iron cores. Every row carries two saturation columns so the rolloff criterion can be chosen explicitly.

    In the HC8LP line-up this part is number 9 of 16 by inductance, between 0.17 uH and 47.9 uH.

    One step down the table, HC8LP-4R5-R, sits at 4.57 uH with 6.5 A and 27.6 mOhm – the lower inductance buys about 1.3 A of extra current in the same body.

    • Core material: powder iron core, 10.9 x 10.4 mm body at 3.5 mm.
    • Typical applications: multi-phase regulators; voltage regulator modules (vrms); distributed power systems dc-dc converters; notebook and laptop regulators; desktop and server vrms and evrds; point-of-load (pol) modules.
    • The two saturation columns are different criteria, not two measurements of the same thing. Pick the rolloff you can tolerate in the application and stay with that column.

    Putting It to Work

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 38.9 mOhm becomes roughly 59.5 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: use the 30% rolloff column only if the loop can tolerate the inductance droop; the tighter column keeps more inductance at the cost of a lower usable peak current.

    • Use the inductance-versus-DC-bias curve for the ripple calculation, not OCL.
    • Compare the two saturation columns before fixing the current limit in the controller.
    • Check that the inductance at the working DC bias still meets the ripple target.

    Frequently Asked Questions

    Which saturation column should I design to?
    The one that matches the inductance droop your loop can tolerate. The 30 % column gives a higher usable peak current; the tighter column keeps more inductance at the cost of headroom.

    What is soft saturation?
    The inductance falls gradually as current rises instead of collapsing at a threshold. A powder core with a distributed gap behaves this way, which keeps the converter stable through a load transient.

    Why is the DCR higher than a ferrite part of the same size?
    Iron powder has lower permeability, so more turns are needed for the same inductance, and more turns mean more copper. The compensation is the much higher saturation flux density.