| Parameter | Value |
|---|---|
| Orderable part number | HC8LP-8R2-R |
| OCL (open circuit inductance) | 8.37 uH ±20% |
| Irms (DC, 40 °C rise) | 4.5 A |
| Isat (15% rolloff) | 4.2 A |
| Isat2 (30% rolloff) | 7.4 A |
| DCR typical @ +20 °C | 58 mOhm |
| Volt-time rating (V-us) | 8.6 |
| Package | 10.9 x 10.4 mm |
| Height | 3.5 mm |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +155 °C (ambient plus self-heating) |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4126 |

Drawing reproduced from Eaton Technical Data 4126: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
This is a surface-mount inductor on a distributed air gap: the powder core spreads the gap through the whole volume, which is why the part tolerates large DC bias without a cliff in the inductance curve, and why it is used on multiphase rails where the inductors share current.
At the rated 4.5 A the winding dissipates about 1.18 W in copper alone, using the typical DCR of 58 mOhm. That figure is the floor of the loss budget: it assumes the current is pure DC, and any ripple adds to it.
The saturation rating reads 15% rolloff. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.
At Isat the part holds about 73.8 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.
The second saturation column, 7.4 A at 30% rolloff, is the same core taken further into rolloff. The ratio between the two columns is a direct measure of how soft the curve is: a part with a wide gap between them loses inductance slowly and tolerates a larger transient peak.
The HC powder family sits at the higher-inductance end of the high-current range: from a fraction of a microhenry up to tens of microhenry, on surface-mount bodies with powder iron cores. Every row carries two saturation columns so the rolloff criterion can be chosen explicitly.
Of the 16 values listed for HC8LP, this is the 11th, in a family covering 0.17 uH to 47.9 uH.
One step down the table, HC8LP-6R9-R, sits at 6.98 uH with 5.2 A and 42.8 mOhm – the lower inductance buys about 0.9 A of extra current in the same body.
Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 58 mOhm becomes roughly 88.8 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: use the 30% rolloff column only if the loop can tolerate the inductance droop; the tighter column keeps more inductance at the cost of a lower usable peak current.
Why is the DCR higher than a ferrite part of the same size?
Iron powder has lower permeability, so more turns are needed for the same inductance, and more turns mean more copper. The compensation is the much higher saturation flux density.
What is soft saturation?
The inductance falls gradually as current rises instead of collapsing at a threshold. A powder core with a distributed gap behaves this way, which keeps the converter stable through a load transient.
Is the part shielded?
The winding is enclosed by the powder core, so the external field is small. It is not a closed ferrite shield, but the fringing field is low enough for dense board layouts.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd