Eaton HC8LP-R75-R 0.830 uH High-Current Inductor 4.7 mOhm
Eaton HC8LP-R75-R 0.830 uH High-Current Inductor 4.7 mOhm

Eaton HC8LP-R75-R 0.830 uH High-Current Inductor 4.7 mOhm

Share
Eaton HC8LP-R75-R: powder iron high-current inductor, 0.830 uH ±20%, 15.6 A Irms, Isat 13.5 A, DCR 4.7 mOhm, 10.9 x 10.4 mm.
    • Product Details
    • Download

    Eaton HC8LP-R75-R 0.830 uH High-Current Inductor 4.7 mOhm

    HC8LP-R75-R at a glance: powder iron high-current inductor, 0.830 uH ±20%, 15.6 A Irms, Isat 13.5 A (15% rolloff), DCR 4.7 mOhm, 10.9 x 10.4 mm.

    Electrical Specifications

    ParameterValue
    Orderable part numberHC8LP-R75-R
    OCL (open circuit inductance)0.830 uH ±20%
    Irms (DC, 40 °C rise)15.6 A
    Isat (15% rolloff)13.5 A
    Isat2 (30% rolloff)24 A
    DCR typical @ +20 °C4.7 mOhm
    Volt-time rating (V-us)3.4
    Package10.9 x 10.4 mm
    Height3.5 mm
    MountingSurface mount
    Operating temperature-40 °C to +155 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4126

    Mechanical Drawing

    HC8LP-R75-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4126: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    The Figures Explained

    This is a surface-mount inductor on a distributed air gap: the powder core spreads the gap through the whole volume, which is why the part tolerates large DC bias without a cliff in the inductance curve, and why it is used on multiphase rails where the inductors share current.

    Copper loss at the rated current works out to roughly 1.14 W from a typical DCR of 4.7 mOhm at 15.6 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.

    Saturation is quoted as 15% rolloff. At that point the inductance has fallen to the stated fraction of its nominal value – the part is not damaged there, it simply stops behaving like the inductance on the label. Design the peak current to stay inside that boundary with margin for tolerance.

    Stored energy at Isat is about 75.6 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.

    The second saturation column, 24 A at 30% rolloff, is the same core taken further into rolloff. The ratio between the two columns is a direct measure of how soft the curve is: a part with a wide gap between them loses inductance slowly and tolerates a larger transient peak.

    Where This Series Fits

    The HC powder family sits at the higher-inductance end of the high-current range: from a fraction of a microhenry up to tens of microhenry, on surface-mount bodies with powder iron cores. Every row carries two saturation columns so the rolloff criterion can be chosen explicitly.

    Of the 16 values listed for HC8LP, this is the 3th, in a family covering 0.17 uH to 47.9 uH.

    Compared with its neighbours in the table, HC8LP-1R2-R trades 7.8 A of rated current for the next inductance step, which is the usual compromise in this family.

    • Core material: powder iron core, 10.9 x 10.4 mm body at 3.5 mm.
    • Typical applications: multi-phase regulators; voltage regulator modules (vrms); distributed power systems dc-dc converters; notebook and laptop regulators; desktop and server vrms and evrds; point-of-load (pol) modules.
    • The two saturation columns are different criteria, not two measurements of the same thing. Pick the rolloff you can tolerate in the application and stay with that column.

    Sizing It Into a Design

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 4.7 mOhm becomes roughly 7.19 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: use the 30% rolloff column only if the loop can tolerate the inductance droop; the tighter column keeps more inductance at the cost of a lower usable peak current.

    • Compare the two saturation columns before fixing the current limit in the controller.
    • Check that the inductance at the working DC bias still meets the ripple target.
    • Decide which rolloff column the loop can tolerate, then stay with that column.

    Frequently Asked Questions

    How do I estimate the inductance at my operating current?
    Read it off the inductance-versus-DC-bias curve in the data sheet at the actual bias. The curve, not the OCL value, is what sets the ripple at load.

    How do I estimate the inductance at my operating current?
    Read it off the inductance-versus-DC-bias curve in the data sheet at the actual bias. The curve, not the OCL value, is what sets the ripple at load.

    How do I estimate the inductance at my operating current?
    Read it off the inductance-versus-DC-bias curve in the data sheet at the actual bias. The curve, not the OCL value, is what sets the ripple at load.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products