Eaton HC9-220-R Powder Iron Inductor 22.4 uH, Isat 6 A
Eaton HC9-220-R Powder Iron Inductor 22.4 uH, Isat 6 A

Eaton HC9-220-R Powder Iron Inductor 22.4 uH, Isat 6 A

Share
Eaton HC9-220-R: powder iron high-current inductor, 22.4 uH ±15%, 6.3 A Irms, Isat 6 A, DCR 25.7 mOhm, 13.1 x 14.1 mm.
    • Product Details
    • Download

    Eaton HC9-220-R Powder Iron Inductor 22.4 uH, Isat 6 A

    HC9-220-R at a glance: powder iron high-current inductor, 22.4 uH ±15%, 6.3 A Irms, Isat 6 A (20% rolloff), DCR 25.7 mOhm, 13.1 x 14.1 mm.

    Electrical Specifications

    ParameterValue
    Orderable part numberHC9-220-R
    OCL (open circuit inductance)22.4 uH ±15%
    Irms (DC, 40 °C rise)6.3 A
    Isat (20% rolloff)6 A
    Isat2 (30% rolloff)8.7 A
    DCR typical @ +20 °C25.7 mOhm
    Volt-time rating (V-us)31.5
    Package13.1 x 14.1 mm
    Height7.5 mm
    MountingSurface mount
    Operating temperature-40 °C to +155 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data DS4312

    Mechanical Drawing

    HC9-220-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data DS4312: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    What the Numbers Mean

    The core is iron powder held in a high-temperature non-organic binder. That construction does not saturate abruptly: as current rises the permeability falls progressively, so the inductance droops instead of collapsing. For a switching regulator working near its current limit during a transient, that behaviour keeps the control loop in a known place.

    At the rated 6.3 A the winding dissipates about 1.02 W in copper alone, using the typical DCR of 25.7 mOhm. That figure is the floor of the loss budget: it assumes the current is pure DC, and any ripple adds to it.

    Isat is specified as 20% rolloff, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.

    Stored energy at Isat is about 403 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.

    The second saturation column, 8.7 A at 30% rolloff, is the same core taken further into rolloff. The ratio between the two columns is a direct measure of how soft the curve is: a part with a wide gap between them loses inductance slowly and tolerates a larger transient peak.

    Where This Series Fits

    The HC powder family sits at the higher-inductance end of the high-current range: from a fraction of a microhenry up to tens of microhenry, on surface-mount bodies with powder iron cores. Every row carries two saturation columns so the rolloff criterion can be chosen explicitly.

    Within the HC9 family this is value 10 of 12, in a range that runs from 0.218 uH to 49.2 uH.

    The next value up in the same family, HC9-330-R, gives 34.5 uH at 4.42 A and DCR 48.8 mOhm: the extra inductance costs about 4.08 A of rated current.

    • Core material: powder iron core, 13.1 x 14.1 mm body at 7.5 mm.
    • Typical applications: multi-phase regulators; voltage regulator modules (vrms); distributed power systems dc-dc converters; desktop and server vrms and evrds; point-of-load (pol) modules; field programmable gate array (fpga) dc-dc converters.
    • The two saturation columns are different criteria, not two measurements of the same thing. Pick the rolloff you can tolerate in the application and stay with that column.

    Design Notes

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 25.7 mOhm becomes roughly 39.3 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: use the 30% rolloff column only if the loop can tolerate the inductance droop; the tighter column keeps more inductance at the cost of a lower usable peak current.

    • Compare the two saturation columns before fixing the current limit in the controller.
    • Confirm the part marking is visible after placement for traceability.
    • Check that the inductance at the working DC bias still meets the ripple target.

    Frequently Asked Questions

    How do I estimate the inductance at my operating current?
    Read it off the inductance-versus-DC-bias curve in the data sheet at the actual bias. The curve, not the OCL value, is what sets the ripple at load.

    How do I estimate the inductance at my operating current?
    Read it off the inductance-versus-DC-bias curve in the data sheet at the actual bias. The curve, not the OCL value, is what sets the ripple at load.

    What is soft saturation?
    The inductance falls gradually as current rises instead of collapsing at a threshold. A powder core with a distributed gap behaves this way, which keeps the converter stable through a load transient.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products