Eaton HC9-2R2-R 2.53 uH SMD Power Inductor, 10.4 V-us
Eaton HC9-2R2-R 2.53 uH SMD Power Inductor, 10.4 V-us

Eaton HC9-2R2-R 2.53 uH SMD Power Inductor, 10.4 V-us

Share
Eaton HC9-2R2-R: powder iron high-current inductor, 2.53 uH ±15%, 17.2 A Irms, Isat 18 A, DCR 3.37 mOhm, 13.1 x 14.1 mm.
    • Product Details
    • Download

    Eaton HC9-2R2-R 2.53 uH SMD Power Inductor, 10.4 V-us

    HC9-2R2-R at a glance: powder iron high-current inductor, 2.53 uH ±15%, 17.2 A Irms, Isat 18 A (20% rolloff), DCR 3.37 mOhm, 13.1 x 14.1 mm.

    Electrical Specifications

    ParameterValue
    Orderable part numberHC9-2R2-R
    OCL (open circuit inductance)2.53 uH ±15%
    Irms (DC, 40 °C rise)17.2 A
    Isat (20% rolloff)18 A
    Isat2 (30% rolloff)26 A
    DCR typical @ +20 °C3.37 mOhm
    Volt-time rating (V-us)10.4
    Package13.1 x 14.1 mm
    Height7.5 mm
    MountingSurface mount
    Operating temperature-40 °C to +155 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data DS4312

    Dimensions and Pad Layout

    HC9-2R2-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data DS4312: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    How to Read These Ratings

    Powder iron is the material choice that gives this family its soft saturation curve and its stable inductance over temperature. There is no thermal aging of the binder, so the inductance you measure on day one is the inductance you have after a thousand thermal cycles.

    With 3.37 mOhm typical, the I-squared-R loss at the full 17.2 A rating is about 0.997 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.

    The saturation rating reads 20% rolloff. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.

    At Isat the part holds about 410 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.

    The second saturation column, 26 A at 30% rolloff, is the same core taken further into rolloff. The ratio between the two columns is a direct measure of how soft the curve is: a part with a wide gap between them loses inductance slowly and tolerates a larger transient peak.

    Positioning in the Range

    The HC powder family sits at the higher-inductance end of the high-current range: from a fraction of a microhenry up to tens of microhenry, on surface-mount bodies with powder iron cores. Every row carries two saturation columns so the rolloff criterion can be chosen explicitly.

    The HC9 family spans 0.218 uH to 49.2 uH; this row sits at position 5 of 12.

    Compared with its neighbours in the table, HC9-3R3-R trades 6.7 A of rated current for the next inductance step, which is the usual compromise in this family.

    • Core material: powder iron core, 13.1 x 14.1 mm body at 7.5 mm.
    • Typical applications: multi-phase regulators; voltage regulator modules (vrms); distributed power systems dc-dc converters; desktop and server vrms and evrds; point-of-load (pol) modules; field programmable gate array (fpga) dc-dc converters.
    • The two saturation columns are different criteria, not two measurements of the same thing. Pick the rolloff you can tolerate in the application and stay with that column.

    Design Notes

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 3.37 mOhm becomes roughly 5.16 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: use the 30% rolloff column only if the loop can tolerate the inductance droop; the tighter column keeps more inductance at the cost of a lower usable peak current.

    • Compare the two saturation columns before fixing the current limit in the controller.
    • Confirm the part marking is visible after placement for traceability.
    • Check the volt-time rating against the applied V-us at the switching frequency.

    Frequently Asked Questions

    What is soft saturation?
    The inductance falls gradually as current rises instead of collapsing at a threshold. A powder core with a distributed gap behaves this way, which keeps the converter stable through a load transient.

    Why is the DCR higher than a ferrite part of the same size?
    Iron powder has lower permeability, so more turns are needed for the same inductance, and more turns mean more copper. The compensation is the much higher saturation flux density.

    Which saturation column should I design to?
    The one that matches the inductance droop your loop can tolerate. The 30 % column gives a higher usable peak current; the tighter column keeps more inductance at the cost of headroom.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products