Eaton HC9-3R3-R Powder Iron Inductor 3.52 uH, Isat 15 A
Eaton HC9-3R3-R Powder Iron Inductor 3.52 uH, Isat 15 A

Eaton HC9-3R3-R Powder Iron Inductor 3.52 uH, Isat 15 A

Share
Eaton HC9-3R3-R: powder iron high-current inductor, 3.52 uH ±15%, 14.3 A Irms, Isat 15 A, DCR 4.87 mOhm, 13.1 x 14.1 mm.
    • Product Details
    • Download

    Eaton HC9-3R3-R Powder Iron Inductor 3.52 uH, Isat 15 A

    HC9-3R3-R at a glance: powder iron high-current inductor, 3.52 uH ±15%, 14.3 A Irms, Isat 15 A (20% rolloff), DCR 4.87 mOhm, 13.1 x 14.1 mm.

    Key Specifications

    ParameterValue
    Orderable part numberHC9-3R3-R
    OCL (open circuit inductance)3.52 uH ±15%
    Irms (DC, 40 °C rise)14.3 A
    Isat (20% rolloff)15 A
    Isat2 (30% rolloff)22 A
    DCR typical @ +20 °C4.87 mOhm
    Volt-time rating (V-us)12.4
    Package13.1 x 14.1 mm
    Height7.5 mm
    MountingSurface mount
    Operating temperature-40 °C to +155 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data DS4312

    Dimensions and Pad Layout

    HC9-3R3-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data DS4312: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    Reading the Data Sheet

    This is a surface-mount inductor on a distributed air gap: the powder core spreads the gap through the whole volume, which is why the part tolerates large DC bias without a cliff in the inductance curve, and why it is used on multiphase rails where the inductors share current.

    The DCR figure of 4.87 mOhm is what sets the efficiency: at 14.3 A the winding drops about 0.07 mV and dissipates 0.996 W. On a low-voltage rail that drop is a measurable fraction of the output, so the DCR column deserves as much attention as the inductance.

    Saturation is quoted as 20% rolloff. At that point the inductance has fallen to the stated fraction of its nominal value – the part is not damaged there, it simply stops behaving like the inductance on the label. Design the peak current to stay inside that boundary with margin for tolerance.

    Energy storage at the saturation current is around 396 uJ, the number that connects the inductance and the current rating into a single transient figure.

    The second saturation column, 22 A at 30% rolloff, is the same core taken further into rolloff. The ratio between the two columns is a direct measure of how soft the curve is: a part with a wide gap between them loses inductance slowly and tolerates a larger transient peak.

    Series Positioning

    The HC powder family sits at the higher-inductance end of the high-current range: from a fraction of a microhenry up to tens of microhenry, on surface-mount bodies with powder iron cores. Every row carries two saturation columns so the rolloff criterion can be chosen explicitly.

    The HC9 family spans 0.218 uH to 49.2 uH; this row sits at position 6 of 12.

    The next value up in the same family, HC9-4R3-R, gives 4.67 uH at 13 A and DCR 5.9 mOhm: the extra inductance costs about 4.2 A of rated current.

    • Core material: powder iron core, 13.1 x 14.1 mm body at 7.5 mm.
    • Typical applications: multi-phase regulators; voltage regulator modules (vrms); distributed power systems dc-dc converters; desktop and server vrms and evrds; point-of-load (pol) modules; field programmable gate array (fpga) dc-dc converters.
    • The two saturation columns are different criteria, not two measurements of the same thing. Pick the rolloff you can tolerate in the application and stay with that column.

    Putting It to Work

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 4.87 mOhm becomes roughly 7.45 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: use the 30% rolloff column only if the loop can tolerate the inductance droop; the tighter column keeps more inductance at the cost of a lower usable peak current.

    • Decide which rolloff column the loop can tolerate, then stay with that column.
    • Compare the two saturation columns before fixing the current limit in the controller.
    • Check that the inductance at the working DC bias still meets the ripple target.

    Frequently Asked Questions

    How do I estimate the inductance at my operating current?
    Read it off the inductance-versus-DC-bias curve in the data sheet at the actual bias. The curve, not the OCL value, is what sets the ripple at load.

    Is the part shielded?
    The winding is enclosed by the powder core, so the external field is small. It is not a closed ferrite shield, but the fringing field is low enough for dense board layouts.

    Is the part shielded?
    The winding is enclosed by the powder core, so the external field is small. It is not a closed ferrite shield, but the fringing field is low enough for dense board layouts.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message