| Parameter | Value |
|---|---|
| Orderable part number | HCF1007-2R2-R |
| OCL (open circuit inductance) | 2.2 uH ±20% |
| FLL minimum, at Isat | 1.57 uH |
| Irms (DC, 40 °C rise) | 10.7 A |
| Isat (20% rolloff @ +25 °C) | 18 A |
| Isat2 (20% rolloff @ +125 °C) | 14 A |
| DCR typical @ +20 °C | 6.35 mOhm |
| K-factor (Bp-p = K x L x dI) | 93.3, Bp-p in Gauss |
| Package | 10.3 x 8.1 mm |
| Height | 6.65 mm |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C (ambient plus self-heating) |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4361 |

Drawing reproduced from Eaton Technical Data 4361: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
This inductor uses a ferrite core with a winding arranged to present a high DC bias resistance. In practice that means the inductance holds up further into the load range than a plain ferrite part of the same size, and the part runs on converters that need low core loss rather than the soft saturation of a powder core.
At the rated 10.7 A the winding dissipates about 0.727 W in copper alone, using the typical DCR of 6.35 mOhm. That figure is the floor of the loss budget: it assumes the current is pure DC, and any ripple adds to it.
The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.
Energy storage at the saturation current is around 356 uJ, the number that connects the inductance and the current rating into a single transient figure.
With K = 93.3, a peak-to-peak ripple of one amp produces roughly 205 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.
The second saturation column, 14 A at 20% rolloff @ +125 °C, is the same core taken further into rolloff. The ratio between the two columns is a direct measure of how soft the curve is: a part with a wide gap between them loses inductance slowly and tolerates a larger transient peak.
The HCF family is the ferrite option in the high-current range: lower core loss than a powder part at high frequency, with saturation current quoted at both +25 °C and +125 °C. It is the family for converters that run fast and hot.
The HCF1007 family spans 0.3 uH to 10 uH; this row sits at position 7 of 12.
Compared with its neighbours in the table, HCF1007-3R3-R trades 3 A of rated current for the next inductance step, which is the usual compromise in this family.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 6.35 mOhm becomes roughly 8.97 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the full-load inductance (FLL) is the value to use for ripple at rated current. OCL is the small-signal number; FLL is what the converter actually sees under load.
What is the difference between OCL and FLL?
OCL is the open-circuit inductance measured at low signal. FLL is the inductance remaining at the saturation current. Ripple at full load should be calculated with FLL, not OCL.
How is the K-factor used?
Multiply K by the inductance in microhenry and by the peak-to-peak ripple in amps to get the flux swing the core sees. Read the core-loss curve at that amplitude and at your switching frequency.
Is this part suitable for current sensing?
The family includes parts with tight DCR tolerance for exactly that purpose, but the tolerance is quoted at +20 °C. Copper drift with temperature has to be compensated in the sensing circuit.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd