| Parameter | Value |
|---|---|
| Orderable part number | HCF1007-R30-R |
| OCL (open circuit inductance) | 0.30 uH ±20% |
| FLL minimum, at Isat | 0.21 uH |
| Irms (DC, 40 °C rise) | 30 A |
| Isat (20% rolloff @ +25 °C) | 48 A |
| Isat2 (20% rolloff @ +125 °C) | 35 A |
| DCR typical @ +20 °C | 0.9 mOhm |
| K-factor (Bp-p = K x L x dI) | 280, Bp-p in Gauss |
| Package | 10.3 x 8.1 mm |
| Height | 6.65 mm |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C (ambient plus self-heating) |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4361 |

Drawing reproduced from Eaton Technical Data 4361: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
This inductor uses a ferrite core with a winding arranged to present a high DC bias resistance. In practice that means the inductance holds up further into the load range than a plain ferrite part of the same size, and the part runs on converters that need low core loss rather than the soft saturation of a powder core.
With 0.9 mOhm typical, the I-squared-R loss at the full 30 A rating is about 0.81 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.
Saturation is quoted as 20% rolloff @ +25 °C. At that point the inductance has fallen to the stated fraction of its nominal value – the part is not damaged there, it simply stops behaving like the inductance on the label. Design the peak current to stay inside that boundary with margin for tolerance.
Energy storage at the saturation current is around 346 uJ, the number that connects the inductance and the current rating into a single transient figure.
With K = 280, a peak-to-peak ripple of one amp produces roughly 84 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.
The second saturation column, 35 A at 20% rolloff @ +125 °C, is the same core taken further into rolloff. The ratio between the two columns is a direct measure of how soft the curve is: a part with a wide gap between them loses inductance slowly and tolerates a larger transient peak.
The HCF family is the ferrite option in the high-current range: lower core loss than a powder part at high frequency, with saturation current quoted at both +25 °C and +125 °C. It is the family for converters that run fast and hot.
In the HCF1007 line-up this part is number 1 of 12 by inductance, between 0.3 uH and 10 uH.
The next value up in the same family, HCF1007-R42-R, gives 0.42 uH at 26 A and DCR 1.3 mOhm: the extra inductance costs about 0 A of rated current.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 0.9 mOhm becomes roughly 1.27 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the full-load inductance (FLL) is the value to use for ripple at rated current. OCL is the small-signal number; FLL is what the converter actually sees under load.
Why are there two saturation currents?
Ferrite loses saturation flux density as it heats. The +25 °C column describes a bench measurement; the +125 °C column describes the part under load in a hot enclosure, which is the one that governs the design.
Is this part suitable for current sensing?
The family includes parts with tight DCR tolerance for exactly that purpose, but the tolerance is quoted at +20 °C. Copper drift with temperature has to be compensated in the sensing circuit.
Is this part suitable for current sensing?
The family includes parts with tight DCR tolerance for exactly that purpose, but the tolerance is quoted at +20 °C. Copper drift with temperature has to be compensated in the sensing circuit.
Shenzhen Gaorunxin Technology Co., Ltd