| Parameter | Value |
|---|---|
| Orderable part number | HCF1007-R56-R |
| OCL (open circuit inductance) | 0.56 uH ±20% |
| FLL minimum, at Isat | 0.4 uH |
| Irms (DC, 40 °C rise) | 26 A |
| Isat (20% rolloff @ +25 °C) | 36 A |
| Isat2 (20% rolloff @ +125 °C) | 28 A |
| DCR typical @ +20 °C | 1.3 mOhm |
| K-factor (Bp-p = K x L x dI) | 187, Bp-p in Gauss |
| Package | 10.3 x 8.1 mm |
| Height | 6.65 mm |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C (ambient plus self-heating) |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4361 |

Drawing reproduced from Eaton Technical Data 4361: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
The core is ferrite, and the family is characterised at two temperatures: the saturation current is quoted at +25 °C and again at +125 °C. That second column is the one that decides whether the part survives a hot corner, because ferrite loses saturation margin as it heats.
Copper loss at the rated current works out to roughly 0.879 W from a typical DCR of 1.3 mOhm at 26 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.
Isat is specified as 20% rolloff @ +25 °C, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.
The core stores roughly 363 uJ at the saturation point – a useful figure when sizing the output capacitance that has to absorb the same transient.
With K = 187, a peak-to-peak ripple of one amp produces roughly 104 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.
The second saturation column, 28 A at 20% rolloff @ +125 °C, is the same core taken further into rolloff. The ratio between the two columns is a direct measure of how soft the curve is: a part with a wide gap between them loses inductance slowly and tolerates a larger transient peak.
The HCF family is the ferrite option in the high-current range: lower core loss than a powder part at high frequency, with saturation current quoted at both +25 °C and +125 °C. It is the family for converters that run fast and hot.
The HCF1007 family spans 0.3 uH to 10 uH; this row sits at position 3 of 12.
Compared with its neighbours in the table, HCF1007-R68-R trades 0 A of rated current for the next inductance step, which is the usual compromise in this family.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 1.3 mOhm becomes roughly 1.84 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the full-load inductance (FLL) is the value to use for ripple at rated current. OCL is the small-signal number; FLL is what the converter actually sees under load.
Why are there two saturation currents?
Ferrite loses saturation flux density as it heats. The +25 °C column describes a bench measurement; the +125 °C column describes the part under load in a hot enclosure, which is the one that governs the design.
How is the K-factor used?
Multiply K by the inductance in microhenry and by the peak-to-peak ripple in amps to get the flux swing the core sees. Read the core-loss curve at that amplitude and at your switching frequency.
How is the K-factor used?
Multiply K by the inductance in microhenry and by the peak-to-peak ripple in amps to get the flux swing the core sees. Read the core-loss curve at that amplitude and at your switching frequency.
Shenzhen Gaorunxin Technology Co., Ltd