Eaton HCF1007-R68-R Ferrite Inductor 0.68 uH, Isat 29 A
Eaton HCF1007-R68-R Ferrite Inductor 0.68 uH, Isat 29 A

Eaton HCF1007-R68-R Ferrite Inductor 0.68 uH, Isat 29 A

Share
Eaton HCF1007-R68-R: ferrite high-current power inductor, 0.68 uH ±20%, 26 A Irms, Isat 29 A, DCR 1.3 mOhm, 10.3 x 8.1 mm.
    • Product Details
    • Download

    Eaton HCF1007-R68-R Ferrite Inductor 0.68 uH, Isat 29 A

    HCF1007-R68-R at a glance: ferrite high-current power inductor, 0.68 uH ±20%, 26 A Irms, Isat 29 A (20% rolloff @ +25 °C), DCR 1.3 mOhm, 10.3 x 8.1 mm.

    Key Specifications

    ParameterValue
    Orderable part numberHCF1007-R68-R
    OCL (open circuit inductance)0.68 uH ±20%
    FLL minimum, at Isat0.49 uH
    Irms (DC, 40 °C rise)26 A
    Isat (20% rolloff @ +25 °C)29 A
    Isat2 (20% rolloff @ +125 °C)23 A
    DCR typical @ +20 °C1.3 mOhm
    K-factor (Bp-p = K x L x dI)187, Bp-p in Gauss
    Package10.3 x 8.1 mm
    Height6.65 mm
    MountingSurface mount
    Operating temperature-40 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4361

    Dimensions and Pad Layout

    HCF1007-R68-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4361: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    How to Read These Ratings

    Ferrite core, high current, and a winding built to keep the DC resistance low: this family sits between the foil-wound parts and the molded powder parts. Ferrite gives low core loss at the switching frequency; the construction gives a low DCR and a tight tolerance, which matters when the inductor is also the current-sense element.

    Copper loss at the rated current works out to roughly 0.879 W from a typical DCR of 1.3 mOhm at 26 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.

    The Isat column is 20% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.

    At Isat the part holds about 286 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.

    The K-factor of 187 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 127 Gauss of Bp-p, the figure the core-loss curve is plotted against.

    The second saturation column, 23 A at 20% rolloff @ +125 °C, is the same core taken further into rolloff. The ratio between the two columns is a direct measure of how soft the curve is: a part with a wide gap between them loses inductance slowly and tolerates a larger transient peak.

    What This Family Is For

    The HCF family is the ferrite option in the high-current range: lower core loss than a powder part at high frequency, with saturation current quoted at both +25 °C and +125 °C. It is the family for converters that run fast and hot.

    The HCF1007 family spans 0.3 uH to 10 uH; this row sits at position 4 of 12.

    Compared with its neighbours in the table, HCF1007-1R0-R trades 10 A of rated current for the next inductance step, which is the usual compromise in this family.

    • Core material: ferrite core, 10.3 x 8.1 mm body at 6.65 mm.
    • Typical applications: voltage regulator modules (vrm); high current dc-dc converters; multi-phase buck regulators; servers and data networking; point-of-load modules.
    • Ferrite loses saturation margin as it heats. The +125 °C Isat column is the one that governs a hot design; the +25 °C figure is the optimistic one.

    Sizing It Into a Design

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 1.3 mOhm becomes roughly 1.84 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the full-load inductance (FLL) is the value to use for ripple at rated current. OCL is the small-signal number; FLL is what the converter actually sees under load.

    • Confirm the terminal arrangement matches the pad layout for three-terminal parts.
    • Use the +125 °C saturation column for the current limit in the controller.
    • Calculate ripple with FLL, not OCL: the loaded inductance is what the converter sees.

    Frequently Asked Questions

    How is the K-factor used?
    Multiply K by the inductance in microhenry and by the peak-to-peak ripple in amps to get the flux swing the core sees. Read the core-loss curve at that amplitude and at your switching frequency.

    Why are there two saturation currents?
    Ferrite loses saturation flux density as it heats. The +25 °C column describes a bench measurement; the +125 °C column describes the part under load in a hot enclosure, which is the one that governs the design.

    What is the difference between OCL and FLL?
    OCL is the open-circuit inductance measured at low signal. FLL is the inductance remaining at the saturation current. Ripple at full load should be calculated with FLL, not OCL.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products