Eaton HCF1305-1R2-R 1.20 uH Ferrite Power Inductor, 22 A
Eaton HCF1305-1R2-R 1.20 uH Ferrite Power Inductor, 22 A

Eaton HCF1305-1R2-R 1.20 uH Ferrite Power Inductor, 22 A

Share
Eaton HCF1305-1R2-R: ferrite high-current power inductor, 1.20 uH ±20%, 22 A Irms, Isat 20 A, DCR 1.58 mOhm, 12.5 x 12.5 mm.
    • Product Details
    • Download

    Eaton HCF1305-1R2-R 1.20 uH Ferrite Power Inductor, 22 A

    HCF1305-1R2-R at a glance: ferrite high-current power inductor, 1.20 uH ±20%, 22 A Irms, Isat 20 A (30% rolloff @ +25 °C), DCR 1.58 mOhm, 12.5 x 12.5 mm.

    Ratings at a Glance

    ParameterValue
    Orderable part numberHCF1305-1R2-R
    Rated inductance1.2 uH ±20%
    OCL (open circuit inductance)1.20 uH ±20%
    Irms (DC, 40 °C rise)22 A
    Isat (30% rolloff @ +25 °C)20 A
    Isat2 (30% rolloff @ +125 °C)15 A
    DCR typical @ +20 °C1.58 mOhm
    DCR maximum @ +20 °C1.9 mOhm
    K-factor (Bp-p = K x L x dI)14, Bp-p in mT
    Package12.5 x 12.5 mm
    Height5.0 mm
    MountingSurface mount
    Operating temperature-40 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4133

    Dimensions and Pad Layout

    HCF1305-1R2-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4133: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    The Figures Explained

    Ferrite, tight DCR, high current: the family is aimed at switching converters where the inductor value has to be known accurately and the loss budget is tight. The data sheet quotes OCL, full-load inductance and saturation current separately so the three can be traded against each other.

    Copper loss at the rated current works out to roughly 0.765 W from a typical DCR of 1.58 mOhm at 22 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.

    The saturation rating reads 30% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.

    At Isat the part holds about 240 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.

    With K = 14, a peak-to-peak ripple of one amp produces roughly 16.8 mT of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.

    The second saturation column, 15 A at 30% rolloff @ +125 °C, is the same core taken further into rolloff. The ratio between the two columns is a direct measure of how soft the curve is: a part with a wide gap between them loses inductance slowly and tolerates a larger transient peak.

    What This Family Is For

    The HCF family is the ferrite option in the high-current range: lower core loss than a powder part at high frequency, with saturation current quoted at both +25 °C and +125 °C. It is the family for converters that run fast and hot.

    Of the 10 values listed for HCF1305, this is the 4th, in a family covering 0.47 uH to 4.7 uH.

    One step down the table, HCF1305-1R0-R, sits at 1.00 uH with 22 A and 1.58 mOhm – the lower inductance buys about 5.7 A of extra current in the same body.

    • Core material: ferrite core, 12.5 x 12.5 mm body at 5.0 mm.
    • Typical applications: voltage regulator modules (vrm); high current dc-dc converters; multi-phase buck regulators; servers and data networking; point-of-load modules.
    • Ferrite loses saturation margin as it heats. The +125 °C Isat column is the one that governs a hot design; the +25 °C figure is the optimistic one.

    Design Notes

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 1.9 mOhm becomes roughly 2.68 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the full-load inductance (FLL) is the value to use for ripple at rated current. OCL is the small-signal number; FLL is what the converter actually sees under load.

    • Check saturation at the +125 °C column when the enclosure runs hot.
    • Calculate ripple with FLL, not OCL: the loaded inductance is what the converter sees.
    • Check saturation at the +125 °C column when the enclosure runs hot.

    Frequently Asked Questions

    Is this part suitable for current sensing?
    The family includes parts with tight DCR tolerance for exactly that purpose, but the tolerance is quoted at +20 °C. Copper drift with temperature has to be compensated in the sensing circuit.

    Why are there two saturation currents?
    Ferrite loses saturation flux density as it heats. The +25 °C column describes a bench measurement; the +125 °C column describes the part under load in a hot enclosure, which is the one that governs the design.

    Is this part suitable for current sensing?
    The family includes parts with tight DCR tolerance for exactly that purpose, but the tolerance is quoted at +20 °C. Copper drift with temperature has to be compensated in the sensing circuit.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products