Eaton HCF1305-1R8-R 1.80 uH Low-Loss Power Inductor
Eaton HCF1305-1R8-R 1.80 uH Low-Loss Power Inductor

Eaton HCF1305-1R8-R 1.80 uH Low-Loss Power Inductor

Share
Eaton HCF1305-1R8-R: ferrite high-current power inductor, 1.80 uH ±20%, 16.3 A Irms, Isat 18 A, DCR 2.58 mOhm, 12.5 x 12.5 mm.
    • Product Details
    • Download

    Eaton HCF1305-1R8-R 1.80 uH Low-Loss Power Inductor

    HCF1305-1R8-R at a glance: ferrite high-current power inductor, 1.80 uH ±20%, 16.3 A Irms, Isat 18 A (30% rolloff @ +25 °C), DCR 2.58 mOhm, 12.5 x 12.5 mm.

    Electrical Specifications

    ParameterValue
    Orderable part numberHCF1305-1R8-R
    Rated inductance1.8 uH ±20%
    OCL (open circuit inductance)1.80 uH ±20%
    Irms (DC, 40 °C rise)16.3 A
    Isat (30% rolloff @ +25 °C)18 A
    Isat2 (30% rolloff @ +125 °C)15 A
    DCR typical @ +20 °C2.58 mOhm
    DCR maximum @ +20 °C3.1 mOhm
    K-factor (Bp-p = K x L x dI)10, Bp-p in mT
    Package12.5 x 12.5 mm
    Height5.0 mm
    MountingSurface mount
    Operating temperature-40 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4133

    Dimensions and Pad Layout

    HCF1305-1R8-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4133: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    The Figures Explained

    Ferrite, tight DCR, high current: the family is aimed at switching converters where the inductor value has to be known accurately and the loss budget is tight. The data sheet quotes OCL, full-load inductance and saturation current separately so the three can be traded against each other.

    Copper loss at the rated current works out to roughly 0.685 W from a typical DCR of 2.58 mOhm at 16.3 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.

    The saturation rating reads 30% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.

    At Isat the part holds about 292 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.

    K-factor 10 means the flux swing is about 18 mT per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.

    The second saturation column, 15 A at 30% rolloff @ +125 °C, is the same core taken further into rolloff. The ratio between the two columns is a direct measure of how soft the curve is: a part with a wide gap between them loses inductance slowly and tolerates a larger transient peak.

    What This Family Is For

    The HCF family is the ferrite option in the high-current range: lower core loss than a powder part at high frequency, with saturation current quoted at both +25 °C and +125 °C. It is the family for converters that run fast and hot.

    Of the 10 values listed for HCF1305, this is the 5th, in a family covering 0.47 uH to 4.7 uH.

    The next value up in the same family, HCF1305-2R2-R, gives 2.20 uH at 16.3 A and DCR 2.58 mOhm: the extra inductance costs about 5.7 A of rated current.

    • Core material: ferrite core, 12.5 x 12.5 mm body at 5.0 mm.
    • Typical applications: voltage regulator modules (vrm); high current dc-dc converters; multi-phase buck regulators; servers and data networking; point-of-load modules.
    • Ferrite loses saturation margin as it heats. The +125 °C Isat column is the one that governs a hot design; the +25 °C figure is the optimistic one.

    Design Notes

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 3.1 mOhm becomes roughly 4.38 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the full-load inductance (FLL) is the value to use for ripple at rated current. OCL is the small-signal number; FLL is what the converter actually sees under load.

    • Check the full-load inductance against the ripple target at maximum load.
    • Confirm the terminal arrangement matches the pad layout for three-terminal parts.
    • Check the full-load inductance against the ripple target at maximum load.

    Frequently Asked Questions

    What happens above the self-resonant frequency?
    The part becomes capacitive and no longer behaves as an inductor. Keep the switching frequency and the harmonics that carry energy comfortably below SRF where one is quoted.

    How is the K-factor used?
    Multiply K by the inductance in microhenry and by the peak-to-peak ripple in amps to get the flux swing the core sees. Read the core-loss curve at that amplitude and at your switching frequency.

    Is a three-terminal part a drop-in for a two-terminal one?
    No. The third terminal is part of the construction and changes the pad layout and the current path, so the board needs the matching footprint.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products