Eaton HCF1305-3R0-R 3.00 uH High-Current Inductor 4.08 mOhm
Eaton HCF1305-3R0-R 3.00 uH High-Current Inductor 4.08 mOhm

Eaton HCF1305-3R0-R 3.00 uH High-Current Inductor 4.08 mOhm

Share
Eaton HCF1305-3R0-R: ferrite high-current power inductor, 3.00 uH ±20%, 13.2 A Irms, Isat 14.4 A, DCR 4.08 mOhm, 12.5 x 12.5 mm.
    • Product Details
    • Download

    Eaton HCF1305-3R0-R 3.00 uH High-Current Inductor 4.08 mOhm

    HCF1305-3R0-R at a glance: ferrite high-current power inductor, 3.00 uH ±20%, 13.2 A Irms, Isat 14.4 A (30% rolloff @ +25 °C), DCR 4.08 mOhm, 12.5 x 12.5 mm.

    Ratings at a Glance

    ParameterValue
    Orderable part numberHCF1305-3R0-R
    Rated inductance3 uH ±20%
    OCL (open circuit inductance)3.00 uH ±20%
    Irms (DC, 40 °C rise)13.2 A
    Isat (30% rolloff @ +25 °C)14.4 A
    Isat2 (30% rolloff @ +125 °C)12 A
    DCR typical @ +20 °C4.08 mOhm
    DCR maximum @ +20 °C4.9 mOhm
    K-factor (Bp-p = K x L x dI)8.3, Bp-p in mT
    Package12.5 x 12.5 mm
    Height5.0 mm
    MountingSurface mount
    Operating temperature-40 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4133

    Mechanical Drawing

    HCF1305-3R0-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4133: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    How to Read These Ratings

    The core is ferrite, and the family is characterised at two temperatures: the saturation current is quoted at +25 °C and again at +125 °C. That second column is the one that decides whether the part survives a hot corner, because ferrite loses saturation margin as it heats.

    Copper loss at the rated current works out to roughly 0.711 W from a typical DCR of 4.08 mOhm at 13.2 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.

    The Isat column is 30% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.

    Stored energy at Isat is about 311 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.

    The K-factor of 8.3 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 24.9 mT of Bp-p, the figure the core-loss curve is plotted against.

    The second saturation column, 12 A at 30% rolloff @ +125 °C, is the same core taken further into rolloff. The ratio between the two columns is a direct measure of how soft the curve is: a part with a wide gap between them loses inductance slowly and tolerates a larger transient peak.

    What This Family Is For

    The HCF family is the ferrite option in the high-current range: lower core loss than a powder part at high frequency, with saturation current quoted at both +25 °C and +125 °C. It is the family for converters that run fast and hot.

    Of the 10 values listed for HCF1305, this is the 7th, in a family covering 0.47 uH to 4.7 uH.

    Compared with its neighbours in the table, HCF1305-3R3-R trades 3.1 A of rated current for the next inductance step, which is the usual compromise in this family.

    • Core material: ferrite core, 12.5 x 12.5 mm body at 5.0 mm.
    • Typical applications: voltage regulator modules (vrm); high current dc-dc converters; multi-phase buck regulators; servers and data networking; point-of-load modules.
    • Ferrite loses saturation margin as it heats. The +125 °C Isat column is the one that governs a hot design; the +25 °C figure is the optimistic one.

    Sizing It Into a Design

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 4.9 mOhm becomes roughly 6.92 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the full-load inductance (FLL) is the value to use for ripple at rated current. OCL is the small-signal number; FLL is what the converter actually sees under load.

    • Use the +125 °C saturation column for the current limit in the controller.
    • Read the core-loss curve at the Bp-p implied by the K-factor and the ripple.
    • Confirm the terminal arrangement matches the pad layout for three-terminal parts.

    Frequently Asked Questions

    What is the difference between OCL and FLL?
    OCL is the open-circuit inductance measured at low signal. FLL is the inductance remaining at the saturation current. Ripple at full load should be calculated with FLL, not OCL.

    How is the K-factor used?
    Multiply K by the inductance in microhenry and by the peak-to-peak ripple in amps to get the flux swing the core sees. Read the core-loss curve at that amplitude and at your switching frequency.

    Why are there two saturation currents?
    Ferrite loses saturation flux density as it heats. The +25 °C column describes a bench measurement; the +125 °C column describes the part under load in a hot enclosure, which is the one that governs the design.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products