Eaton HCF1305-4R0-R 4.00 uH Low-Loss Power Inductor
Eaton HCF1305-4R0-R 4.00 uH Low-Loss Power Inductor

Eaton HCF1305-4R0-R 4.00 uH Low-Loss Power Inductor

Share
Eaton HCF1305-4R0-R: ferrite high-current power inductor, 4.00 uH ±20%, 10.9 A Irms, Isat 12 A, DCR 6 mOhm, 12.5 x 12.5 mm.
    • Product Details
    • Download

    Eaton HCF1305-4R0-R 4.00 uH Low-Loss Power Inductor

    HCF1305-4R0-R at a glance: ferrite high-current power inductor, 4.00 uH ±20%, 10.9 A Irms, Isat 12 A (30% rolloff @ +25 °C), DCR 6 mOhm, 12.5 x 12.5 mm.

    Key Specifications

    ParameterValue
    Orderable part numberHCF1305-4R0-R
    Rated inductance4 uH ±20%
    OCL (open circuit inductance)4.00 uH ±20%
    Irms (DC, 40 °C rise)10.9 A
    Isat (30% rolloff @ +25 °C)12 A
    Isat2 (30% rolloff @ +125 °C)10 A
    DCR typical @ +20 °C6 mOhm
    DCR maximum @ +20 °C7.2 mOhm
    K-factor (Bp-p = K x L x dI)6.9, Bp-p in mT
    Package12.5 x 12.5 mm
    Height5.0 mm
    MountingSurface mount
    Operating temperature-40 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4133

    Mechanical Dimensions & Pad Layout

    HCF1305-4R0-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4133: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    What the Numbers Mean

    The core is ferrite, and the family is characterised at two temperatures: the saturation current is quoted at +25 °C and again at +125 °C. That second column is the one that decides whether the part survives a hot corner, because ferrite loses saturation margin as it heats.

    The DCR figure of 6 mOhm is what sets the efficiency: at 10.9 A the winding drops about 0.065 mV and dissipates 0.713 W. On a low-voltage rail that drop is a measurable fraction of the output, so the DCR column deserves as much attention as the inductance.

    Isat is specified as 30% rolloff @ +25 °C, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.

    The core stores roughly 288 uJ at the saturation point – a useful figure when sizing the output capacitance that has to absorb the same transient.

    K-factor 6.9 means the flux swing is about 27.6 mT per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.

    The second saturation column, 10 A at 30% rolloff @ +125 °C, is the same core taken further into rolloff. The ratio between the two columns is a direct measure of how soft the curve is: a part with a wide gap between them loses inductance slowly and tolerates a larger transient peak.

    Series Positioning

    The HCF family is the ferrite option in the high-current range: lower core loss than a powder part at high frequency, with saturation current quoted at both +25 °C and +125 °C. It is the family for converters that run fast and hot.

    Of the 10 values listed for HCF1305, this is the 9th, in a family covering 0.47 uH to 4.7 uH.

    The next value up in the same family, HCF1305-4R7-R, gives 4.70 uH at 10.9 A and DCR 6 mOhm: the extra inductance costs about 2.3 A of rated current.

    • Core material: ferrite core, 12.5 x 12.5 mm body at 5.0 mm.
    • Typical applications: voltage regulator modules (vrm); high current dc-dc converters; multi-phase buck regulators; servers and data networking; point-of-load modules.
    • Ferrite loses saturation margin as it heats. The +125 °C Isat column is the one that governs a hot design; the +25 °C figure is the optimistic one.

    Sizing and Layout Notes

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 7.2 mOhm becomes roughly 10.2 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the full-load inductance (FLL) is the value to use for ripple at rated current. OCL is the small-signal number; FLL is what the converter actually sees under load.

    • Calculate ripple with FLL, not OCL: the loaded inductance is what the converter sees.
    • Check saturation at the +125 °C column when the enclosure runs hot.
    • Confirm the terminal arrangement matches the pad layout for three-terminal parts.

    Frequently Asked Questions

    What happens above the self-resonant frequency?
    The part becomes capacitive and no longer behaves as an inductor. Keep the switching frequency and the harmonics that carry energy comfortably below SRF where one is quoted.

    Is a three-terminal part a drop-in for a two-terminal one?
    No. The third terminal is part of the construction and changes the pad layout and the current path, so the board needs the matching footprint.

    What happens above the self-resonant frequency?
    The part becomes capacitive and no longer behaves as an inductor. Keep the switching frequency and the harmonics that carry energy comfortably below SRF where one is quoted.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products