| Parameter | Value |
|---|---|
| Orderable part number | HCF1305-R56-R |
| Rated inductance | 0.56 uH ±20% |
| OCL (open circuit inductance) | 0.56 uH ±20% |
| Irms (DC, 40 °C rise) | 32 A |
| Isat (30% rolloff @ +25 °C) | 30 A |
| Isat2 (30% rolloff @ +125 °C) | 22.5 A |
| DCR typical @ +20 °C | 0.83 mOhm |
| DCR maximum @ +20 °C | 1 mOhm |
| K-factor (Bp-p = K x L x dI) | 21, Bp-p in mT |
| Package | 12.5 x 12.5 mm |
| Height | 5.0 mm |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C (ambient plus self-heating) |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4133 |

Drawing reproduced from Eaton Technical Data 4133: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
Ferrite core, high current, and a winding built to keep the DC resistance low: this family sits between the foil-wound parts and the molded powder parts. Ferrite gives low core loss at the switching frequency; the construction gives a low DCR and a tight tolerance, which matters when the inductor is also the current-sense element.
At the rated 32 A the winding dissipates about 0.85 W in copper alone, using the typical DCR of 0.83 mOhm. That figure is the floor of the loss budget: it assumes the current is pure DC, and any ripple adds to it.
The Isat column is 30% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.
The core stores roughly 252 uJ at the saturation point – a useful figure when sizing the output capacitance that has to absorb the same transient.
With K = 21, a peak-to-peak ripple of one amp produces roughly 11.8 mT of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.
The second saturation column, 22.5 A at 30% rolloff @ +125 °C, is the same core taken further into rolloff. The ratio between the two columns is a direct measure of how soft the curve is: a part with a wide gap between them loses inductance slowly and tolerates a larger transient peak.
The HCF family is the ferrite option in the high-current range: lower core loss than a powder part at high frequency, with saturation current quoted at both +25 °C and +125 °C. It is the family for converters that run fast and hot.
Of the 10 values listed for HCF1305, this is the 2th, in a family covering 0.47 uH to 4.7 uH.
The next value up in the same family, HCF1305-1R0-R, gives 1.00 uH at 22 A and DCR 1.58 mOhm: the extra inductance costs about 10 A of rated current.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 1 mOhm becomes roughly 1.41 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the full-load inductance (FLL) is the value to use for ripple at rated current. OCL is the small-signal number; FLL is what the converter actually sees under load.
Why are there two saturation currents?
Ferrite loses saturation flux density as it heats. The +25 °C column describes a bench measurement; the +125 °C column describes the part under load in a hot enclosure, which is the one that governs the design.
Why are there two saturation currents?
Ferrite loses saturation flux density as it heats. The +25 °C column describes a bench measurement; the +125 °C column describes the part under load in a hot enclosure, which is the one that governs the design.
How is the K-factor used?
Multiply K by the inductance in microhenry and by the peak-to-peak ripple in amps to get the flux swing the core sees. Read the core-loss curve at that amplitude and at your switching frequency.