Eaton HCM0503-2R2-R Molded Inductor 2.2 uH, Isat 6.5 A
Eaton HCM0503-2R2-R Molded Inductor 2.2 uH, Isat 6.5 A

Eaton HCM0503-2R2-R Molded Inductor 2.2 uH, Isat 6.5 A

Share
Eaton HCM0503-2R2-R: molded high-current power inductor, 2.2 uH ±20%, 6.8 A Irms, Isat 6.5 A, DCR 22.5 mOhm, 5.5 x 5.3 mm.
    • Product Details
    • Download

    Eaton HCM0503-2R2-R Molded Inductor 2.2 uH, Isat 6.5 A

    HCM0503-2R2-R at a glance: molded high-current power inductor, 2.2 uH ±20%, 6.8 A Irms, Isat 6.5 A (20% rolloff @ +25 °C), DCR 22.5 mOhm, 5.5 x 5.3 mm.

    Key Specifications

    ParameterValue
    Orderable part numberHCM0503-2R2-R
    OCL (open circuit inductance)2.2 uH ±20%
    FLL minimum, at Isat1.4 uH
    Irms (DC, 40 °C rise)6.8 A
    Isat (20% rolloff @ +25 °C)6.5 A
    DCR typical @ +20 °C22.5 mOhm
    DCR maximum @ +20 °C25 mOhm
    K-factor (Bp-p = K x L x dI)325, Bp-p in Gauss
    Package5.5 x 5.3 mm
    Height3.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4430

    Dimensions and Pad Layout

    HCM0503-2R2-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4430: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    The Figures Explained

    The part is a surface-mount molded inductor: powder core, directly wound and pressed, with the terminals formed from the winding ends. The absence of a bobbin or an air gap in the magnetic path is what keeps the DCR low for the current rating, and the soft saturation is a property of the distributed gap.

    Copper loss at the rated current works out to roughly 1.04 W from a typical DCR of 22.5 mOhm at 6.8 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.

    The Isat column is 20% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.

    Energy storage at the saturation current is around 46.5 uJ, the number that connects the inductance and the current rating into a single transient figure.

    With K = 325, a peak-to-peak ripple of one amp produces roughly 715 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.

    What This Family Is For

    The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.

    The HCM0503 family spans 0.2 uH to 22 uH; this row sits at position 7 of 13.

    The next value up in the same family, HCM0503-3R3-R, gives 3.3 uH at 5.5 A and DCR 36.4 mOhm: the extra inductance costs about 2 A of rated current.

    • Core material: iron powder core, 5.5 x 5.3 mm body at 3.0 mm.
    • Typical applications: voltage regulator module (vrm); multi-phase regulators; point-of-load modules; desktop and server vrms and evrds; base station equipment; notebook and laptop regulators.
    • The DCR columns are typical and maximum at +20 °C. Copper rises about 0.4 % per °C, so the hot resistance is higher than either column suggests.

    Putting It to Work

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 25 mOhm becomes roughly 35.3 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.

    • Allow for copper drift: resistance rises with temperature at roughly 0.4 % per °C.
    • Allow for copper drift: resistance rises with temperature at roughly 0.4 % per °C.
    • Confirm the shielding is adequate for the adjacent trace routing.

    Frequently Asked Questions

    How much does the inductance drop at rated current?
    That is what the Isat column quantifies. At the rated DC current the part is still inside the rolloff boundary, but the ripple calculation should use the FLL column rather than OCL.

    How much does the inductance drop at rated current?
    That is what the Isat column quantifies. At the rated DC current the part is still inside the rolloff boundary, but the ripple calculation should use the FLL column rather than OCL.

    How much inductance is left at rated current?
    That is what the saturation column describes. Isat is the peak current at which inductance has fallen by the stated percentage, so at the rated DC current the part is still inside that boundary.

    Shenzhen Gaorunxin Technology Co., Ltd