| Parameter | Value |
|---|---|
| Orderable part number | HCM0503-2R2-R |
| OCL (open circuit inductance) | 2.2 uH ±20% |
| FLL minimum, at Isat | 1.4 uH |
| Irms (DC, 40 °C rise) | 6.8 A |
| Isat (20% rolloff @ +25 °C) | 6.5 A |
| DCR typical @ +20 °C | 22.5 mOhm |
| DCR maximum @ +20 °C | 25 mOhm |
| K-factor (Bp-p = K x L x dI) | 325, Bp-p in Gauss |
| Package | 5.5 x 5.3 mm |
| Height | 3.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C (ambient plus self-heating) |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4430 |

Drawing reproduced from Eaton Technical Data 4430: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
The part is a surface-mount molded inductor: powder core, directly wound and pressed, with the terminals formed from the winding ends. The absence of a bobbin or an air gap in the magnetic path is what keeps the DCR low for the current rating, and the soft saturation is a property of the distributed gap.
Copper loss at the rated current works out to roughly 1.04 W from a typical DCR of 22.5 mOhm at 6.8 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.
The Isat column is 20% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.
Energy storage at the saturation current is around 46.5 uJ, the number that connects the inductance and the current rating into a single transient figure.
With K = 325, a peak-to-peak ripple of one amp produces roughly 715 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.
The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.
The HCM0503 family spans 0.2 uH to 22 uH; this row sits at position 7 of 13.
The next value up in the same family, HCM0503-3R3-R, gives 3.3 uH at 5.5 A and DCR 36.4 mOhm: the extra inductance costs about 2 A of rated current.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 25 mOhm becomes roughly 35.3 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.
How much does the inductance drop at rated current?
That is what the Isat column quantifies. At the rated DC current the part is still inside the rolloff boundary, but the ripple calculation should use the FLL column rather than OCL.
How much does the inductance drop at rated current?
That is what the Isat column quantifies. At the rated DC current the part is still inside the rolloff boundary, but the ripple calculation should use the FLL column rather than OCL.
How much inductance is left at rated current?
That is what the saturation column describes. Isat is the peak current at which inductance has fallen by the stated percentage, so at the rated DC current the part is still inside that boundary.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd