| Parameter | Value |
|---|---|
| Orderable part number | HCM0503-4R7-R |
| OCL (open circuit inductance) | 4.7 uH ±20% |
| FLL minimum, at Isat | 3 uH |
| Irms (DC, 40 °C rise) | 4.5 A |
| Isat (20% rolloff @ +25 °C) | 5.5 A |
| DCR typical @ +20 °C | 54 mOhm |
| DCR maximum @ +20 °C | 60 mOhm |
| K-factor (Bp-p = K x L x dI) | 226, Bp-p in Gauss |
| Package | 5.5 x 5.3 mm |
| Height | 3.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C (ambient plus self-heating) |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4430 |

Drawing reproduced from Eaton Technical Data 4430: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
The part is a surface-mount molded inductor: powder core, directly wound and pressed, with the terminals formed from the winding ends. The absence of a bobbin or an air gap in the magnetic path is what keeps the DCR low for the current rating, and the soft saturation is a property of the distributed gap.
With 54 mOhm typical, the I-squared-R loss at the full 4.5 A rating is about 1.09 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.
Saturation is quoted as 20% rolloff @ +25 °C. At that point the inductance has fallen to the stated fraction of its nominal value – the part is not damaged there, it simply stops behaving like the inductance on the label. Design the peak current to stay inside that boundary with margin for tolerance.
Energy storage at the saturation current is around 71.1 uJ, the number that connects the inductance and the current rating into a single transient figure.
The K-factor of 226 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 1,062 Gauss of Bp-p, the figure the core-loss curve is plotted against.
The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.
Within the HCM0503 family this is value 9 of 13, in a range that runs from 0.2 uH to 22 uH.
The next value up in the same family, HCM0503-5R6-R, gives 5.6 uH at 4.3 A and DCR 63 mOhm: the extra inductance costs about 1.2 A of rated current.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 60 mOhm becomes roughly 84.8 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.
How much does the inductance drop at rated current?
That is what the Isat column quantifies. At the rated DC current the part is still inside the rolloff boundary, but the ripple calculation should use the FLL column rather than OCL.
Is it magnetically shielded?
Yes. The powder core surrounds the winding, so the leakage field is small and the part can sit close to sensitive traces without a shield can.
Is it magnetically shielded?
Yes. The powder core surrounds the winding, so the leakage field is small and the part can sit close to sensitive traces without a shield can.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd