| Parameter | Value |
|---|---|
| Orderable part number | HCM0503-R20-R |
| OCL (open circuit inductance) | 0.20 uH ±20% |
| FLL minimum, at Isat | 0.13 uH |
| Irms (DC, 40 °C rise) | 22.2 A |
| Isat (20% rolloff @ +25 °C) | 21 A |
| DCR typical @ +20 °C | 2.1 mOhm |
| DCR maximum @ +20 °C | 2.31 mOhm |
| K-factor (Bp-p = K x L x dI) | 1,764, Bp-p in Gauss |
| Package | 5.5 x 5.3 mm |
| Height | 3.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C (ambient plus self-heating) |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4430 |

Drawing reproduced from Eaton Technical Data 4430: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
A molded body around an alloy or iron powder core: the winding is pressed into the magnetic material, so the field is contained inside the part and the terminals come straight out of the molding. The result is a shielded inductor with a low profile and a soft saturation curve, on a footprint that is almost all magnetic material.
With 2.1 mOhm typical, the I-squared-R loss at the full 22.2 A rating is about 1.03 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.
Isat is specified as 20% rolloff @ +25 °C, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.
Stored energy at Isat is about 44.1 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.
The K-factor of 1,764 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 353 Gauss of Bp-p, the figure the core-loss curve is plotted against.
The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.
The HCM0503 family spans 0.2 uH to 22 uH; this row sits at position 1 of 13.
The next value up in the same family, HCM0503-R35-R, gives 0.35 uH at 16.6 A and DCR 3.9 mOhm: the extra inductance costs about 0 A of rated current.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 2.31 mOhm becomes roughly 3.26 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.
How much does the inductance drop at rated current?
That is what the Isat column quantifies. At the rated DC current the part is still inside the rolloff boundary, but the ripple calculation should use the FLL column rather than OCL.
Can two parts be stacked for higher current?
Stacking halves the inductance and doubles the current capability in theory, but the two DCRs are not matched and the magnetic coupling is uncontrolled. Use a larger part instead.
What makes a molded inductor different?
The winding is pressed into the magnetic powder with no bobbin or air gap in the path. That is why the body is almost all magnetic material, the DCR is low for the size, and the part is mechanically robust.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd