| Parameter | Value |
|---|---|
| Orderable part number | HCM0503-R35-R |
| OCL (open circuit inductance) | 0.35 uH ±20% |
| FLL minimum, at Isat | 0.22 uH |
| Irms (DC, 40 °C rise) | 16.6 A |
| Isat (20% rolloff @ +25 °C) | 14.9 A |
| DCR typical @ +20 °C | 3.9 mOhm |
| DCR maximum @ +20 °C | 4.29 mOhm |
| K-factor (Bp-p = K x L x dI) | 1,259, Bp-p in Gauss |
| Package | 5.5 x 5.3 mm |
| Height | 3.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C (ambient plus self-heating) |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4430 |

Drawing reproduced from Eaton Technical Data 4430: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
This is one of the molded power inductors used across VRM, point-of-load and multiphase regulator designs. The family covers a wide inductance range in standard footprints, and every row is characterised for both typical and maximum DCR so the loss budget can be built either way.
Copper loss at the rated current works out to roughly 1.07 W from a typical DCR of 3.9 mOhm at 16.6 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.
The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.
The core stores roughly 38.9 uJ at the saturation point – a useful figure when sizing the output capacitance that has to absorb the same transient.
The K-factor of 1,259 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 441 Gauss of Bp-p, the figure the core-loss curve is plotted against.
The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.
The HCM0503 family spans 0.2 uH to 22 uH; this row sits at position 2 of 13.
Compared with its neighbours in the table, HCM0503-R47-R trades 10.2 A of rated current for the next inductance step, which is the usual compromise in this family.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 4.29 mOhm becomes roughly 6.06 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.
How much does the inductance drop at rated current?
That is what the Isat column quantifies. At the rated DC current the part is still inside the rolloff boundary, but the ripple calculation should use the FLL column rather than OCL.
Why quote typical and maximum DCR?
A guaranteed thermal design uses the maximum. A nominal efficiency calculation uses the typical. Publishing both lets the same table serve either purpose.
What makes a molded inductor different?
The winding is pressed into the magnetic powder with no bobbin or air gap in the path. That is why the body is almost all magnetic material, the DCR is low for the size, and the part is mechanically robust.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd