| Parameter | Value |
|---|---|
| Orderable part number | HCM0703-1R0-R |
| OCL (open circuit inductance) | 1.0 uH ±20% |
| FLL minimum, at Isat | 0.6 uH |
| Irms (DC, 40 °C rise) | 11 A |
| Isat (20% rolloff @ +25 °C) | 22 A |
| DCR typical @ +20 °C | 9 mOhm |
| DCR maximum @ +20 °C | 10 mOhm |
| K-factor (Bp-p = K x L x dI) | 374, Bp-p in Gauss |
| Package | 7.4 x 6.8 mm |
| Height | 3.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C (ambient plus self-heating) |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4085 |

Drawing reproduced from Eaton Technical Data 4085: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
Molded construction is what gives this family its mechanical robustness and its shielding. Because the core surrounds the winding on all sides, the leakage field that would otherwise couple into adjacent traces is small, and the part can be placed close to sensitive nodes.
At the rated 11 A the winding dissipates about 1.09 W in copper alone, using the typical DCR of 9 mOhm. That figure is the floor of the loss budget: it assumes the current is pure DC, and any ripple adds to it.
Saturation is quoted as 20% rolloff @ +25 °C. At that point the inductance has fallen to the stated fraction of its nominal value – the part is not damaged there, it simply stops behaving like the inductance on the label. Design the peak current to stay inside that boundary with margin for tolerance.
Energy storage at the saturation current is around 242 uJ, the number that connects the inductance and the current rating into a single transient figure.
The K-factor of 374 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 374 Gauss of Bp-p, the figure the core-loss curve is plotted against.
The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.
The HCM0703 family spans 0.15 uH to 33 uH; this row sits at position 6 of 16.
One step down the table, HCM0703-R82-R, sits at 0.82 uH with 13 A and 6.7 mOhm – the lower inductance buys about 4 A of extra current in the same body.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 10 mOhm becomes roughly 14.1 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.
How much inductance is left at rated current?
That is what the saturation column describes. Isat is the peak current at which inductance has fallen by the stated percentage, so at the rated DC current the part is still inside that boundary.
What makes a molded inductor different?
The winding is pressed into the magnetic powder with no bobbin or air gap in the path. That is why the body is almost all magnetic material, the DCR is low for the size, and the part is mechanically robust.
Is it magnetically shielded?
Yes. The powder core surrounds the winding, so the leakage field is small and the part can sit close to sensitive traces without a shield can.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd