Eaton HCM0703-R47-R 0.47 uH High-Current Inductor 4 mOhm
Eaton HCM0703-R47-R 0.47 uH High-Current Inductor 4 mOhm

Eaton HCM0703-R47-R 0.47 uH High-Current Inductor 4 mOhm

Share
Eaton HCM0703-R47-R: molded high-current power inductor, 0.47 uH ±20%, 17.5 A Irms, Isat 26 A, DCR 4 mOhm, 7.4 x 6.8 mm.
    • Product Details
    • Download

    Eaton HCM0703-R47-R 0.47 uH High-Current Inductor 4 mOhm

    HCM0703-R47-R at a glance: molded high-current power inductor, 0.47 uH ±20%, 17.5 A Irms, Isat 26 A (20% rolloff @ +25 °C), DCR 4 mOhm, 7.4 x 6.8 mm.

    Ratings at a Glance

    ParameterValue
    Orderable part numberHCM0703-R47-R
    OCL (open circuit inductance)0.47 uH ±20%
    FLL minimum, at Isat0.28 uH
    Irms (DC, 40 °C rise)17.5 A
    Isat (20% rolloff @ +25 °C)26 A
    DCR typical @ +20 °C4 mOhm
    DCR maximum @ +20 °C4.2 mOhm
    K-factor (Bp-p = K x L x dI)580, Bp-p in Gauss
    Package7.4 x 6.8 mm
    Height3.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4085

    Mechanical Dimensions & Pad Layout

    HCM0703-R47-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4085: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    What the Numbers Mean

    A molded body around an alloy or iron powder core: the winding is pressed into the magnetic material, so the field is contained inside the part and the terminals come straight out of the molding. The result is a shielded inductor with a low profile and a soft saturation curve, on a footprint that is almost all magnetic material.

    At the rated 17.5 A the winding dissipates about 1.23 W in copper alone, using the typical DCR of 4 mOhm. That figure is the floor of the loss budget: it assumes the current is pure DC, and any ripple adds to it.

    The Isat column is 20% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.

    The core stores roughly 159 uJ at the saturation point – a useful figure when sizing the output capacitance that has to absorb the same transient.

    K-factor 580 means the flux swing is about 273 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.

    What This Family Is For

    The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.

    The HCM0703 family spans 0.15 uH to 33 uH; this row sits at position 3 of 16.

    One step down the table, HCM0703-R22-R, sits at 0.22 uH with 23 A and 2.5 mOhm – the lower inductance buys about 7.5 A of extra current in the same body.

    • Core material: iron powder core, 7.4 x 6.8 mm body at 3.0 mm.
    • Typical applications: voltage regulator module (vrm); multi-phase regulators; point-of-loadmodules; desktop and server vrms and evrds; base station equipment; laptop and notebook regulators.
    • The DCR columns are typical and maximum at +20 °C. Copper rises about 0.4 % per °C, so the hot resistance is higher than either column suggests.

    Putting It to Work

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 4.2 mOhm becomes roughly 5.93 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.

    • Build the thermal design on the maximum DCR, not the typical one.
    • Allow for copper drift: resistance rises with temperature at roughly 0.4 % per °C.
    • Check the hot DCR before signing off the efficiency budget.

    Frequently Asked Questions

    How much inductance is left at rated current?
    That is what the saturation column describes. Isat is the peak current at which inductance has fallen by the stated percentage, so at the rated DC current the part is still inside that boundary.

    Why quote typical and maximum DCR?
    A guaranteed thermal design uses the maximum. A nominal efficiency calculation uses the typical. Publishing both lets the same table serve either purpose.

    How much does the inductance drop at rated current?
    That is what the Isat column quantifies. At the rated DC current the part is still inside the rolloff boundary, but the ripple calculation should use the FLL column rather than OCL.