Eaton HCM1103-1R0-R Molded Inductor 1.0 uH, Isat 21 A
Eaton HCM1103-1R0-R Molded Inductor 1.0 uH, Isat 21 A

Eaton HCM1103-1R0-R Molded Inductor 1.0 uH, Isat 21 A

Share
Eaton HCM1103-1R0-R: molded high-current power inductor, 1.0 uH ±20%, 15 A Irms, Isat 21 A, DCR 5.5 mOhm, 11.5 x 10.3 mm.
    • Product Details
    • Download

    Eaton HCM1103-1R0-R Molded Inductor 1.0 uH, Isat 21 A

    HCM1103-1R0-R at a glance: molded high-current power inductor, 1.0 uH ±20%, 15 A Irms, Isat 21 A (20% rolloff @ +25 °C), DCR 5.5 mOhm, 11.5 x 10.3 mm.

    Electrical Specifications

    ParameterValue
    Orderable part numberHCM1103-1R0-R
    OCL (open circuit inductance)1.0 uH ±20%
    FLL minimum, at Isat0.56 uH
    Irms (DC, 40 °C rise)15 A
    Isat (20% rolloff @ +25 °C)21 A
    DCR typical @ +20 °C5.5 mOhm
    DCR maximum @ +20 °C6 mOhm
    K-factor (Bp-p = K x L x dI)377, Bp-p in Gauss
    Package11.5 x 10.3 mm
    Height3.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4449

    Outline Drawing

    HCM1103-1R0-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4449: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    The Figures Explained

    The part is a surface-mount molded inductor: powder core, directly wound and pressed, with the terminals formed from the winding ends. The absence of a bobbin or an air gap in the magnetic path is what keeps the DCR low for the current rating, and the soft saturation is a property of the distributed gap.

    With 5.5 mOhm typical, the I-squared-R loss at the full 15 A rating is about 1.24 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.

    Isat is specified as 20% rolloff @ +25 °C, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.

    Energy storage at the saturation current is around 220 uJ, the number that connects the inductance and the current rating into a single transient figure.

    K-factor 377 means the flux swing is about 377 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.

    Series Positioning

    The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.

    Of the 12 values listed for HCM1103, this is the 5th, in a family covering 0.12 uH to 22 uH.

    Compared with its neighbours in the table, HCM1103-2R2-R trades 8 A of rated current for the next inductance step, which is the usual compromise in this family.

    • Core material: iron powder core, 11.5 x 10.3 mm body at 3.0 mm.
    • Typical applications: voltage regulator module (vrm); multi-phase regulators; point-of-load modules; desktop and server vrms and evrds; base station equipment; notebook and laptop regulators.
    • The DCR columns are typical and maximum at +20 °C. Copper rises about 0.4 % per °C, so the hot resistance is higher than either column suggests.

    Sizing and Layout Notes

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 6 mOhm becomes roughly 8.48 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.

    • Confirm the shielding is adequate for the adjacent trace routing.
    • Confirm the shielding is adequate for the adjacent trace routing.
    • Verify the body height against the enclosure or heat-spreader clearance.

    Frequently Asked Questions

    What makes a molded inductor different?
    The winding is pressed into the magnetic powder with no bobbin or air gap in the path. That is why the body is almost all magnetic material, the DCR is low for the size, and the part is mechanically robust.

    How much inductance is left at rated current?
    That is what the saturation column describes. Isat is the peak current at which inductance has fallen by the stated percentage, so at the rated DC current the part is still inside that boundary.

    Can two parts be stacked for higher current?
    Stacking halves the inductance and doubles the current capability in theory, but the two DCRs are not matched and the magnetic coupling is uncontrolled. Use a larger part instead.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd