Eaton HCM1103-3R3-R 3.3 uH Molded Power Inductor, 9 A
Eaton HCM1103-3R3-R 3.3 uH Molded Power Inductor, 9 A

Eaton HCM1103-3R3-R 3.3 uH Molded Power Inductor, 9 A

Share
Eaton HCM1103-3R3-R: molded high-current power inductor, 3.3 uH ±20%, 9 A Irms, Isat 14 A, DCR 14.5 mOhm, 11.5 x 10.3 mm.
    • Product Details
    • Download

    Eaton HCM1103-3R3-R 3.3 uH Molded Power Inductor, 9 A

    HCM1103-3R3-R at a glance: molded high-current power inductor, 3.3 uH ±20%, 9 A Irms, Isat 14 A (20% rolloff @ +25 °C), DCR 14.5 mOhm, 11.5 x 10.3 mm.

    Electrical Specifications

    ParameterValue
    Orderable part numberHCM1103-3R3-R
    OCL (open circuit inductance)3.3 uH ±20%
    FLL minimum, at Isat1.9 uH
    Irms (DC, 40 °C rise)9 A
    Isat (20% rolloff @ +25 °C)14 A
    DCR typical @ +20 °C14.5 mOhm
    DCR maximum @ +20 °C16 mOhm
    K-factor (Bp-p = K x L x dI)230, Bp-p in Gauss
    Package11.5 x 10.3 mm
    Height3.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4449

    Mechanical Dimensions & Pad Layout

    HCM1103-3R3-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4449: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    The Figures Explained

    The part is a surface-mount molded inductor: powder core, directly wound and pressed, with the terminals formed from the winding ends. The absence of a bobbin or an air gap in the magnetic path is what keeps the DCR low for the current rating, and the soft saturation is a property of the distributed gap.

    With 14.5 mOhm typical, the I-squared-R loss at the full 9 A rating is about 1.18 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.

    Saturation is quoted as 20% rolloff @ +25 °C. At that point the inductance has fallen to the stated fraction of its nominal value – the part is not damaged there, it simply stops behaving like the inductance on the label. Design the peak current to stay inside that boundary with margin for tolerance.

    The core stores roughly 323 uJ at the saturation point – a useful figure when sizing the output capacitance that has to absorb the same transient.

    K-factor 230 means the flux swing is about 759 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.

    Series Positioning

    The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.

    Of the 12 values listed for HCM1103, this is the 7th, in a family covering 0.12 uH to 22 uH.

    The next value up in the same family, HCM1103-4R7-R, gives 4.7 uH at 7 A and DCR 20.5 mOhm: the extra inductance costs about 6 A of rated current.

    • Core material: iron powder core, 11.5 x 10.3 mm body at 3.0 mm.
    • Typical applications: voltage regulator module (vrm); multi-phase regulators; point-of-load modules; desktop and server vrms and evrds; base station equipment; notebook and laptop regulators.
    • The DCR columns are typical and maximum at +20 °C. Copper rises about 0.4 % per °C, so the hot resistance is higher than either column suggests.

    Putting It to Work

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 16 mOhm becomes roughly 22.6 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.

    • Confirm the peak transient current stays under Isat with tolerance margin.
    • Confirm the peak transient current stays under Isat with tolerance margin.
    • Build the thermal design on the maximum DCR, not the typical one.

    Frequently Asked Questions

    How much does the inductance drop at rated current?
    That is what the Isat column quantifies. At the rated DC current the part is still inside the rolloff boundary, but the ripple calculation should use the FLL column rather than OCL.

    Is it magnetically shielded?
    Yes. The powder core surrounds the winding, so the leakage field is small and the part can sit close to sensitive traces without a shield can.

    How much does the inductance drop at rated current?
    That is what the Isat column quantifies. At the rated DC current the part is still inside the rolloff boundary, but the ripple calculation should use the FLL column rather than OCL.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products