Eaton HCM1103-4R7-R 4.7 uH Shielded Power Inductor
Eaton HCM1103-4R7-R 4.7 uH Shielded Power Inductor

Eaton HCM1103-4R7-R 4.7 uH Shielded Power Inductor

Share
Eaton HCM1103-4R7-R: molded high-current power inductor, 4.7 uH ±20%, 7 A Irms, Isat 13 A, DCR 20.5 mOhm, 11.5 x 10.3 mm.
    • Product Details
    • Download

    Eaton HCM1103-4R7-R 4.7 uH Shielded Power Inductor

    HCM1103-4R7-R at a glance: molded high-current power inductor, 4.7 uH ±20%, 7 A Irms, Isat 13 A (20% rolloff @ +25 °C), DCR 20.5 mOhm, 11.5 x 10.3 mm.

    Key Specifications

    ParameterValue
    Orderable part numberHCM1103-4R7-R
    OCL (open circuit inductance)4.7 uH ±20%
    FLL minimum, at Isat2.6 uH
    Irms (DC, 40 °C rise)7 A
    Isat (20% rolloff @ +25 °C)13 A
    DCR typical @ +20 °C20.5 mOhm
    DCR maximum @ +20 °C22.5 mOhm
    K-factor (Bp-p = K x L x dI)205, Bp-p in Gauss
    Package11.5 x 10.3 mm
    Height3.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4449

    Outline Drawing

    HCM1103-4R7-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4449: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    The Figures Explained

    This is one of the molded power inductors used across VRM, point-of-load and multiphase regulator designs. The family covers a wide inductance range in standard footprints, and every row is characterised for both typical and maximum DCR so the loss budget can be built either way.

    With 20.5 mOhm typical, the I-squared-R loss at the full 7 A rating is about 1 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.

    The Isat column is 20% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.

    Energy storage at the saturation current is around 397 uJ, the number that connects the inductance and the current rating into a single transient figure.

    The K-factor of 205 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 964 Gauss of Bp-p, the figure the core-loss curve is plotted against.

    Positioning in the Range

    The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.

    Of the 12 values listed for HCM1103, this is the 8th, in a family covering 0.12 uH to 22 uH.

    The next value up in the same family, HCM1103-8R2-R, gives 8.2 uH at 5 A and DCR 35 mOhm: the extra inductance costs about 4 A of rated current.

    • Core material: iron powder core, 11.5 x 10.3 mm body at 3.0 mm.
    • Typical applications: voltage regulator module (vrm); multi-phase regulators; point-of-load modules; desktop and server vrms and evrds; base station equipment; notebook and laptop regulators.
    • The DCR columns are typical and maximum at +20 °C. Copper rises about 0.4 % per °C, so the hot resistance is higher than either column suggests.

    Putting It to Work

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 22.5 mOhm becomes roughly 31.8 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.

    • Allow for copper drift: resistance rises with temperature at roughly 0.4 % per °C.
    • Allow for copper drift: resistance rises with temperature at roughly 0.4 % per °C.
    • Allow for copper drift: resistance rises with temperature at roughly 0.4 % per °C.

    Frequently Asked Questions

    Why quote typical and maximum DCR?
    A guaranteed thermal design uses the maximum. A nominal efficiency calculation uses the typical. Publishing both lets the same table serve either purpose.

    How much inductance is left at rated current?
    That is what the saturation column describes. Isat is the peak current at which inductance has fallen by the stated percentage, so at the rated DC current the part is still inside that boundary.

    Is it magnetically shielded?
    Yes. The powder core surrounds the winding, so the leakage field is small and the part can sit close to sensitive traces without a shield can.