| Parameter | Value |
|---|---|
| Orderable part number | HCM1103-8R2-R |
| OCL (open circuit inductance) | 8.2 uH ±20% |
| FLL minimum, at Isat | 4.6 uH |
| Irms (DC, 40 °C rise) | 5 A |
| Isat (20% rolloff @ +25 °C) | 8.5 A |
| DCR typical @ +20 °C | 35 mOhm |
| DCR maximum @ +20 °C | 38.5 mOhm |
| K-factor (Bp-p = K x L x dI) | 153, Bp-p in Gauss |
| Package | 11.5 x 10.3 mm |
| Height | 3.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C (ambient plus self-heating) |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4449 |

Drawing reproduced from Eaton Technical Data 4449: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
Molded construction is what gives this family its mechanical robustness and its shielding. Because the core surrounds the winding on all sides, the leakage field that would otherwise couple into adjacent traces is small, and the part can be placed close to sensitive nodes.
Copper loss at the rated current works out to roughly 0.875 W from a typical DCR of 35 mOhm at 5 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.
Saturation is quoted as 20% rolloff @ +25 °C. At that point the inductance has fallen to the stated fraction of its nominal value – the part is not damaged there, it simply stops behaving like the inductance on the label. Design the peak current to stay inside that boundary with margin for tolerance.
Energy storage at the saturation current is around 296 uJ, the number that connects the inductance and the current rating into a single transient figure.
With K = 153, a peak-to-peak ripple of one amp produces roughly 1,255 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.
The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.
Within the HCM1103 family this is value 9 of 12, in a range that runs from 0.12 uH to 22 uH.
One step down the table, HCM1103-4R7-R, sits at 4.7 uH with 7 A and 20.5 mOhm – the lower inductance buys about 2 A of extra current in the same body.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 38.5 mOhm becomes roughly 54.4 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.
Is it magnetically shielded?
Yes. The powder core surrounds the winding, so the leakage field is small and the part can sit close to sensitive traces without a shield can.
Why quote typical and maximum DCR?
A guaranteed thermal design uses the maximum. A nominal efficiency calculation uses the typical. Publishing both lets the same table serve either purpose.
How much inductance is left at rated current?
That is what the saturation column describes. Isat is the peak current at which inductance has fallen by the stated percentage, so at the rated DC current the part is still inside that boundary.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd