
| Parameter | Value |
|---|---|
| Orderable part number | HCM1103-R12-R |
| OCL (open circuit inductance) | 0.12 uH ±20% |
| FLL minimum, at Isat | 0.07 uH |
| Irms (DC, 40 °C rise) | 30 A |
| Isat (20% rolloff @ +25 °C) | 75 A |
| DCR typical @ +20 °C | 0.55 mOhm |
| DCR maximum @ +20 °C | 0.61 mOhm |
| K-factor (Bp-p = K x L x dI) | 1,200, Bp-p in Gauss |
| Package | 11.5 x 10.3 mm |
| Height | 3.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C (ambient plus self-heating) |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4449 |

Drawing reproduced from Eaton Technical Data 4449: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
This is one of the molded power inductors used across VRM, point-of-load and multiphase regulator designs. The family covers a wide inductance range in standard footprints, and every row is characterised for both typical and maximum DCR so the loss budget can be built either way.
Copper loss at the rated current works out to roughly 0.495 W from a typical DCR of 0.55 mOhm at 30 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.
Saturation is quoted as 20% rolloff @ +25 °C. At that point the inductance has fallen to the stated fraction of its nominal value – the part is not damaged there, it simply stops behaving like the inductance on the label. Design the peak current to stay inside that boundary with margin for tolerance.
Stored energy at Isat is about 338 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.
With K = 1,200, a peak-to-peak ripple of one amp produces roughly 144 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.
The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.
Of the 12 values listed for HCM1103, this is the 1th, in a family covering 0.12 uH to 22 uH.
One step down the table, HCM1103-R36-R, sits at 0.36 uH with 23 A and 1.1 mOhm – the lower inductance buys about 0 A of extra current in the same body.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 0.61 mOhm becomes roughly 0.862 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.
Can two parts be stacked for higher current?
Stacking halves the inductance and doubles the current capability in theory, but the two DCRs are not matched and the magnetic coupling is uncontrolled. Use a larger part instead.
Why quote typical and maximum DCR?
A guaranteed thermal design uses the maximum. A nominal efficiency calculation uses the typical. Publishing both lets the same table serve either purpose.
Why quote typical and maximum DCR?
A guaranteed thermal design uses the maximum. A nominal efficiency calculation uses the typical. Publishing both lets the same table serve either purpose.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd