
| Parameter | Value |
|---|---|
| Orderable part number | HCM1103-R36-R |
| OCL (open circuit inductance) | 0.36 uH ±20% |
| FLL minimum, at Isat | 0.26 uH |
| Irms (DC, 40 °C rise) | 23 A |
| Isat (20% rolloff @ +25 °C) | 28 A |
| DCR typical @ +20 °C | 1.1 mOhm |
| DCR maximum @ +20 °C | 1.3 mOhm |
| K-factor (Bp-p = K x L x dI) | 711, Bp-p in Gauss |
| Package | 11.5 x 10.3 mm |
| Height | 3.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C (ambient plus self-heating) |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4449 |

Drawing reproduced from Eaton Technical Data 4449: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
A molded body around an alloy or iron powder core: the winding is pressed into the magnetic material, so the field is contained inside the part and the terminals come straight out of the molding. The result is a shielded inductor with a low profile and a soft saturation curve, on a footprint that is almost all magnetic material.
Copper loss at the rated current works out to roughly 0.582 W from a typical DCR of 1.1 mOhm at 23 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.
Isat is specified as 20% rolloff @ +25 °C, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.
At Isat the part holds about 141 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.
The K-factor of 711 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 256 Gauss of Bp-p, the figure the core-loss curve is plotted against.
The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.
Of the 12 values listed for HCM1103, this is the 2th, in a family covering 0.12 uH to 22 uH.
One step down the table, HCM1103-R12-R, sits at 0.12 uH with 30 A and 0.55 mOhm – the lower inductance buys about 10 A of extra current in the same body.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 1.3 mOhm becomes roughly 1.84 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.
How much does the inductance drop at rated current?
That is what the Isat column quantifies. At the rated DC current the part is still inside the rolloff boundary, but the ripple calculation should use the FLL column rather than OCL.
Why quote typical and maximum DCR?
A guaranteed thermal design uses the maximum. A nominal efficiency calculation uses the typical. Publishing both lets the same table serve either purpose.
Is it magnetically shielded?
Yes. The powder core surrounds the winding, so the leakage field is small and the part can sit close to sensitive traces without a shield can.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd