| Parameter | Value |
|---|---|
| Orderable part number | HCM1104-100-R |
| OCL (open circuit inductance) | 10 uH ±20% |
| FLL minimum, at Isat | 5.6 uH |
| Irms (DC, 40 °C rise) | 7.5 A |
| Isat (20% rolloff @ +25 °C) | 8.5 A |
| DCR typical @ +20 °C | 27 mOhm |
| DCR maximum @ +20 °C | 30 mOhm |
| K-factor (Bp-p = K x L x dI) | 116, Bp-p in Gauss |
| Package | 11.5 x 10.3 mm |
| Height | 4.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C (ambient plus self-heating) |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4370 |

Drawing reproduced from Eaton Technical Data 4370: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
Molded construction is what gives this family its mechanical robustness and its shielding. Because the core surrounds the winding on all sides, the leakage field that would otherwise couple into adjacent traces is small, and the part can be placed close to sensitive nodes.
At the rated 7.5 A the winding dissipates about 1.52 W in copper alone, using the typical DCR of 27 mOhm. That figure is the floor of the loss budget: it assumes the current is pure DC, and any ripple adds to it.
The Isat column is 20% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.
The core stores roughly 361 uJ at the saturation point – a useful figure when sizing the output capacitance that has to absorb the same transient.
The K-factor of 116 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 1,160 Gauss of Bp-p, the figure the core-loss curve is plotted against.
The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.
Of the 12 values listed for HCM1104, this is the 11th, in a family covering 0.2 uH to 22 uH.
Compared with its neighbours in the table, HCM1104-220-R trades 3.5 A of rated current for the next inductance step, which is the usual compromise in this family.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 30 mOhm becomes roughly 42.4 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.
Is it magnetically shielded?
Yes. The powder core surrounds the winding, so the leakage field is small and the part can sit close to sensitive traces without a shield can.
How much does the inductance drop at rated current?
That is what the Isat column quantifies. At the rated DC current the part is still inside the rolloff boundary, but the ripple calculation should use the FLL column rather than OCL.
What makes a molded inductor different?
The winding is pressed into the magnetic powder with no bobbin or air gap in the path. That is why the body is almost all magnetic material, the DCR is low for the size, and the part is mechanically robust.