| Parameter | Value |
|---|---|
| Orderable part number | HCM1104-2R2-R |
| OCL (open circuit inductance) | 2.2 uH ±20% |
| FLL minimum, at Isat | 1.23 uH |
| Irms (DC, 40 °C rise) | 12 A |
| Isat (20% rolloff @ +25 °C) | 18 A |
| DCR typical @ +20 °C | 6 mOhm |
| DCR maximum @ +20 °C | 7 mOhm |
| K-factor (Bp-p = K x L x dI) | 253, Bp-p in Gauss |
| Package | 11.5 x 10.3 mm |
| Height | 4.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C (ambient plus self-heating) |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4370 |

Drawing reproduced from Eaton Technical Data 4370: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
This is one of the molded power inductors used across VRM, point-of-load and multiphase regulator designs. The family covers a wide inductance range in standard footprints, and every row is characterised for both typical and maximum DCR so the loss budget can be built either way.
With 6 mOhm typical, the I-squared-R loss at the full 12 A rating is about 0.864 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.
Saturation is quoted as 20% rolloff @ +25 °C. At that point the inductance has fallen to the stated fraction of its nominal value – the part is not damaged there, it simply stops behaving like the inductance on the label. Design the peak current to stay inside that boundary with margin for tolerance.
At Isat the part holds about 356 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.
The K-factor of 253 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 557 Gauss of Bp-p, the figure the core-loss curve is plotted against.
The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.
The HCM1104 family spans 0.2 uH to 22 uH; this row sits at position 8 of 12.
One step down the table, HCM1104-1R5-R, sits at 1.5 uH with 16 A and 3.8 mOhm – the lower inductance buys about 6 A of extra current in the same body.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 7 mOhm becomes roughly 9.89 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.
Can two parts be stacked for higher current?
Stacking halves the inductance and doubles the current capability in theory, but the two DCRs are not matched and the magnetic coupling is uncontrolled. Use a larger part instead.
Can two parts be stacked for higher current?
Stacking halves the inductance and doubles the current capability in theory, but the two DCRs are not matched and the magnetic coupling is uncontrolled. Use a larger part instead.
Is it magnetically shielded?
Yes. The powder core surrounds the winding, so the leakage field is small and the part can sit close to sensitive traces without a shield can.