Eaton HCM1104-4R7-R 4.7 uH High-Current Inductor 17 mOhm
Eaton HCM1104-4R7-R 4.7 uH High-Current Inductor 17 mOhm

Eaton HCM1104-4R7-R 4.7 uH High-Current Inductor 17 mOhm

Share
Eaton HCM1104-4R7-R: molded high-current power inductor, 4.7 uH ±20%, 8.5 A Irms, Isat 15 A, DCR 17 mOhm, 11.5 x 10.3 mm.
    • Product Details
    • Download

    Eaton HCM1104-4R7-R 4.7 uH High-Current Inductor 17 mOhm

    HCM1104-4R7-R at a glance: molded high-current power inductor, 4.7 uH ±20%, 8.5 A Irms, Isat 15 A (20% rolloff @ +25 °C), DCR 17 mOhm, 11.5 x 10.3 mm.

    Ratings at a Glance

    ParameterValue
    Orderable part numberHCM1104-4R7-R
    OCL (open circuit inductance)4.7 uH ±20%
    FLL minimum, at Isat2.63 uH
    Irms (DC, 40 °C rise)8.5 A
    Isat (20% rolloff @ +25 °C)15 A
    DCR typical @ +20 °C17 mOhm
    DCR maximum @ +20 °C20 mOhm
    K-factor (Bp-p = K x L x dI)175, Bp-p in Gauss
    Package11.5 x 10.3 mm
    Height4.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4370

    Mechanical Dimensions & Pad Layout

    HCM1104-4R7-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4370: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    The Figures Explained

    The part is a surface-mount molded inductor: powder core, directly wound and pressed, with the terminals formed from the winding ends. The absence of a bobbin or an air gap in the magnetic path is what keeps the DCR low for the current rating, and the soft saturation is a property of the distributed gap.

    With 17 mOhm typical, the I-squared-R loss at the full 8.5 A rating is about 1.23 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.

    The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.

    Stored energy at Isat is about 529 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.

    With K = 175, a peak-to-peak ripple of one amp produces roughly 822 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.

    Positioning in the Range

    The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.

    Within the HCM1104 family this is value 10 of 12, in a range that runs from 0.2 uH to 22 uH.

    One step down the table, HCM1104-3R3-R, sits at 3.3 uH with 10 A and 10.8 mOhm – the lower inductance buys about 2.5 A of extra current in the same body.

    • Core material: iron powder core, 11.5 x 10.3 mm body at 4.0 mm.
    • Typical applications: voltage regulator module (vrm); multi-phase regulators; point-of-load modules; desktop and server vrms and evrds; base station equipment; notebook and laptop regulators.
    • The DCR columns are typical and maximum at +20 °C. Copper rises about 0.4 % per °C, so the hot resistance is higher than either column suggests.

    Design Notes

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 20 mOhm becomes roughly 28.3 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.

    • Allow for copper drift: resistance rises with temperature at roughly 0.4 % per °C.
    • Build the thermal design on the maximum DCR, not the typical one.
    • Check the hot DCR before signing off the efficiency budget.

    Frequently Asked Questions

    Is it magnetically shielded?
    Yes. The powder core surrounds the winding, so the leakage field is small and the part can sit close to sensitive traces without a shield can.

    How much inductance is left at rated current?
    That is what the saturation column describes. Isat is the peak current at which inductance has fallen by the stated percentage, so at the rated DC current the part is still inside that boundary.

    Why quote typical and maximum DCR?
    A guaranteed thermal design uses the maximum. A nominal efficiency calculation uses the typical. Publishing both lets the same table serve either purpose.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products