    HCM1104-R56-R at a glance: molded high-current power inductor, 0.56 uH ±20%, 25 A Irms, Isat 32 A (20% rolloff @ +25 °C), DCR 1.56 mOhm, 11.5 x 10.3 mm.

    Ratings at a Glance

    ParameterValue
    Orderable part numberHCM1104-R56-R
    OCL (open circuit inductance)0.56 uH ±20%
    FLL minimum, at Isat0.36 uH
    Irms (DC, 40 °C rise)25 A
    Isat (20% rolloff @ +25 °C)32 A
    DCR typical @ +20 °C1.56 mOhm
    DCR maximum @ +20 °C1.8 mOhm
    K-factor (Bp-p = K x L x dI)230, Bp-p in Gauss
    Package11.5 x 10.3 mm
    Height4.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4370

    Dimensions and Pad Layout

    HCM1104-R56-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4370: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    What the Numbers Mean

    Molded construction is what gives this family its mechanical robustness and its shielding. Because the core surrounds the winding on all sides, the leakage field that would otherwise couple into adjacent traces is small, and the part can be placed close to sensitive nodes.

    The DCR figure of 1.56 mOhm is what sets the efficiency: at 25 A the winding drops about 0.039 mV and dissipates 0.975 W. On a low-voltage rail that drop is a measurable fraction of the output, so the DCR column deserves as much attention as the inductance.

    Saturation is quoted as 20% rolloff @ +25 °C. At that point the inductance has fallen to the stated fraction of its nominal value – the part is not damaged there, it simply stops behaving like the inductance on the label. Design the peak current to stay inside that boundary with margin for tolerance.

    Energy storage at the saturation current is around 287 uJ, the number that connects the inductance and the current rating into a single transient figure.

    With K = 230, a peak-to-peak ripple of one amp produces roughly 129 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.

    Series Positioning

    The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.

    Of the 12 values listed for HCM1104, this is the 4th, in a family covering 0.2 uH to 22 uH.

    Compared with its neighbours in the table, HCM1104-R90-R trades 7 A of rated current for the next inductance step, which is the usual compromise in this family.

    • Core material: iron powder core, 11.5 x 10.3 mm body at 4.0 mm.
    • Typical applications: voltage regulator module (vrm); multi-phase regulators; point-of-load modules; desktop and server vrms and evrds; base station equipment; notebook and laptop regulators.
    • The DCR columns are typical and maximum at +20 °C. Copper rises about 0.4 % per °C, so the hot resistance is higher than either column suggests.

    Putting It to Work

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 1.8 mOhm becomes roughly 2.54 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.

    • Confirm the peak transient current stays under Isat with tolerance margin.
    • Confirm the shielding is adequate for the adjacent trace routing.
    • Confirm the shielding is adequate for the adjacent trace routing.

    Frequently Asked Questions

    How much inductance is left at rated current?
    That is what the saturation column describes. Isat is the peak current at which inductance has fallen by the stated percentage, so at the rated DC current the part is still inside that boundary.

    How much inductance is left at rated current?
    That is what the saturation column describes. Isat is the peak current at which inductance has fallen by the stated percentage, so at the rated DC current the part is still inside that boundary.

    How much inductance is left at rated current?
    That is what the saturation column describes. Isat is the peak current at which inductance has fallen by the stated percentage, so at the rated DC current the part is still inside that boundary.