| Parameter | Value |
|---|---|
| Orderable part number | HCM1104-R90-R |
| OCL (open circuit inductance) | 0.90 uH ±20% |
| FLL minimum, at Isat | 0.58 uH |
| Irms (DC, 40 °C rise) | 22 A |
| Isat (20% rolloff @ +25 °C) | 28 A |
| DCR typical @ +20 °C | 2.17 mOhm |
| DCR maximum @ +20 °C | 2.5 mOhm |
| K-factor (Bp-p = K x L x dI) | 236, Bp-p in Gauss |
| Package | 11.5 x 10.3 mm |
| Height | 4.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C (ambient plus self-heating) |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4370 |

Drawing reproduced from Eaton Technical Data 4370: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
A molded body around an alloy or iron powder core: the winding is pressed into the magnetic material, so the field is contained inside the part and the terminals come straight out of the molding. The result is a shielded inductor with a low profile and a soft saturation curve, on a footprint that is almost all magnetic material.
With 2.17 mOhm typical, the I-squared-R loss at the full 22 A rating is about 1.05 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.
The Isat column is 20% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.
Stored energy at Isat is about 353 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.
The K-factor of 236 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 212 Gauss of Bp-p, the figure the core-loss curve is plotted against.
The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.
In the HCM1104 line-up this part is number 5 of 12 by inductance, between 0.2 uH and 22 uH.
Compared with its neighbours in the table, HCM1104-1R0-R trades 7 A of rated current for the next inductance step, which is the usual compromise in this family.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 2.5 mOhm becomes roughly 3.53 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.
How much inductance is left at rated current?
That is what the saturation column describes. Isat is the peak current at which inductance has fallen by the stated percentage, so at the rated DC current the part is still inside that boundary.
How much inductance is left at rated current?
That is what the saturation column describes. Isat is the peak current at which inductance has fallen by the stated percentage, so at the rated DC current the part is still inside that boundary.
What makes a molded inductor different?
The winding is pressed into the magnetic powder with no bobbin or air gap in the path. That is why the body is almost all magnetic material, the DCR is low for the size, and the part is mechanically robust.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd