| Parameter | Value |
|---|---|
| Orderable part number | HCM1305-1R0-R |
| OCL (open circuit inductance) | 1.00 uH ±20% |
| FLL minimum, at Isat | 0.64 uH |
| Irms (DC, 40 °C rise) | 29 A |
| Isat (20% rolloff @ +25 °C) | 50 A |
| DCR typical @ +20 °C | 2.1 mOhm |
| DCR maximum @ +20 °C | 2.42 mOhm |
| K-factor (Bp-p = K x L x dI) | 275, Bp-p in Gauss |
| Package | 13.8 x 12.5 mm |
| Height | 5.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C (ambient plus self-heating) |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4371 |

Drawing reproduced from Eaton Technical Data 4371: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
Molded construction is what gives this family its mechanical robustness and its shielding. Because the core surrounds the winding on all sides, the leakage field that would otherwise couple into adjacent traces is small, and the part can be placed close to sensitive nodes.
With 2.1 mOhm typical, the I-squared-R loss at the full 29 A rating is about 1.77 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.
Isat is specified as 20% rolloff @ +25 °C, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.
Stored energy at Isat is about 1,250 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.
With K = 275, a peak-to-peak ripple of one amp produces roughly 275 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.
The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.
Within the HCM1305 family this is value 8 of 21, in a range that runs from 0.1 uH to 33 uH.
One step down the table, HCM1305-R82-R, sits at 0.82 uH with 31 A and 1.4 mOhm – the lower inductance buys about 8 A of extra current in the same body.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 2.42 mOhm becomes roughly 3.42 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.
How much inductance is left at rated current?
That is what the saturation column describes. Isat is the peak current at which inductance has fallen by the stated percentage, so at the rated DC current the part is still inside that boundary.
Is it magnetically shielded?
Yes. The powder core surrounds the winding, so the leakage field is small and the part can sit close to sensitive traces without a shield can.
Why quote typical and maximum DCR?
A guaranteed thermal design uses the maximum. A nominal efficiency calculation uses the typical. Publishing both lets the same table serve either purpose.