| Parameter | Value |
|---|---|
| Orderable part number | HCM1305-1R5-R |
| OCL (open circuit inductance) | 1.50 uH ±20% |
| FLL minimum, at Isat | 0.96 uH |
| Irms (DC, 40 °C rise) | 23 A |
| Isat (20% rolloff @ +25 °C) | 48 A |
| DCR typical @ +20 °C | 2.75 mOhm |
| DCR maximum @ +20 °C | 3.16 mOhm |
| K-factor (Bp-p = K x L x dI) | 225, Bp-p in Gauss |
| Package | 13.8 x 12.5 mm |
| Height | 5.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C (ambient plus self-heating) |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4371 |

Drawing reproduced from Eaton Technical Data 4371: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
Molded construction is what gives this family its mechanical robustness and its shielding. Because the core surrounds the winding on all sides, the leakage field that would otherwise couple into adjacent traces is small, and the part can be placed close to sensitive nodes.
Copper loss at the rated current works out to roughly 1.46 W from a typical DCR of 2.75 mOhm at 23 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.
Isat is specified as 20% rolloff @ +25 °C, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.
The core stores roughly 1,728 uJ at the saturation point – a useful figure when sizing the output capacitance that has to absorb the same transient.
With K = 225, a peak-to-peak ripple of one amp produces roughly 338 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.
The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.
Of the 21 values listed for HCM1305, this is the 9th, in a family covering 0.1 uH to 33 uH.
The next value up in the same family, HCM1305-1R8-R, gives 1.80 uH at 21 A and DCR 4 mOhm: the extra inductance costs about 8 A of rated current.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 3.16 mOhm becomes roughly 4.46 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.
What makes a molded inductor different?
The winding is pressed into the magnetic powder with no bobbin or air gap in the path. That is why the body is almost all magnetic material, the DCR is low for the size, and the part is mechanically robust.
Why quote typical and maximum DCR?
A guaranteed thermal design uses the maximum. A nominal efficiency calculation uses the typical. Publishing both lets the same table serve either purpose.
Why quote typical and maximum DCR?
A guaranteed thermal design uses the maximum. A nominal efficiency calculation uses the typical. Publishing both lets the same table serve either purpose.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd