Eaton HCM1305-3R3-R 3.30 uH Molded Power Inductor, 15 A
Eaton HCM1305-3R3-R 3.30 uH Molded Power Inductor, 15 A

Eaton HCM1305-3R3-R 3.30 uH Molded Power Inductor, 15 A

Share
Eaton HCM1305-3R3-R: molded high-current power inductor, 3.30 uH ±20%, 15 A Irms, Isat 32 A, DCR 7.7 mOhm, 13.8 x 12.5 mm.
    • Product Details
    • Download

    Eaton HCM1305-3R3-R 3.30 uH Molded Power Inductor, 15 A

    HCM1305-3R3-R at a glance: molded high-current power inductor, 3.30 uH ±20%, 15 A Irms, Isat 32 A (20% rolloff @ +25 °C), DCR 7.7 mOhm, 13.8 x 12.5 mm.

    Specification Table

    ParameterValue
    Orderable part numberHCM1305-3R3-R
    OCL (open circuit inductance)3.30 uH ±20%
    FLL minimum, at Isat2.11 uH
    Irms (DC, 40 °C rise)15 A
    Isat (20% rolloff @ +25 °C)32 A
    DCR typical @ +20 °C7.7 mOhm
    DCR maximum @ +20 °C9.2 mOhm
    K-factor (Bp-p = K x L x dI)170, Bp-p in Gauss
    Package13.8 x 12.5 mm
    Height5.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4371

    Mechanical Dimensions & Pad Layout

    HCM1305-3R3-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4371: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    The Figures Explained

    The part is a surface-mount molded inductor: powder core, directly wound and pressed, with the terminals formed from the winding ends. The absence of a bobbin or an air gap in the magnetic path is what keeps the DCR low for the current rating, and the soft saturation is a property of the distributed gap.

    Copper loss at the rated current works out to roughly 1.73 W from a typical DCR of 7.7 mOhm at 15 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.

    Saturation is quoted as 20% rolloff @ +25 °C. At that point the inductance has fallen to the stated fraction of its nominal value – the part is not damaged there, it simply stops behaving like the inductance on the label. Design the peak current to stay inside that boundary with margin for tolerance.

    Stored energy at Isat is about 1,690 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.

    With K = 170, a peak-to-peak ripple of one amp produces roughly 561 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.

    Where This Series Fits

    The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.

    In the HCM1305 line-up this part is number 12 of 21 by inductance, between 0.1 uH and 33 uH.

    The next value up in the same family, HCM1305-4R7-R, gives 4.70 uH at 12 A and DCR 11 mOhm: the extra inductance costs about 8 A of rated current.

    • Core material: iron powder core, 13.8 x 12.5 mm body at 5.0 mm.
    • Typical applications: voltage regulator module (vrm); multi-phase regulators; point-of-load modules; desktop and server vrms and evrds; base station equipment; notebook and laptop regulators.
    • The DCR columns are typical and maximum at +20 °C. Copper rises about 0.4 % per °C, so the hot resistance is higher than either column suggests.

    Sizing It Into a Design

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 9.2 mOhm becomes roughly 13 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.

    • Check the hot DCR before signing off the efficiency budget.
    • Verify the body height against the enclosure or heat-spreader clearance.
    • Verify the body height against the enclosure or heat-spreader clearance.

    Frequently Asked Questions

    How much inductance is left at rated current?
    That is what the saturation column describes. Isat is the peak current at which inductance has fallen by the stated percentage, so at the rated DC current the part is still inside that boundary.

    Why quote typical and maximum DCR?
    A guaranteed thermal design uses the maximum. A nominal efficiency calculation uses the typical. Publishing both lets the same table serve either purpose.

    Why quote typical and maximum DCR?
    A guaranteed thermal design uses the maximum. A nominal efficiency calculation uses the typical. Publishing both lets the same table serve either purpose.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products