Eaton HCM1305-4R7-R: molded high-current power inductor, 4.70 uH ±20%, 12 A Irms, Isat 27 A, DCR 11 mOhm, 13.8 x 12.5 mm.
    • Product Details
    • Download

    Eaton HCM1305-4R7-R 4.70 uH Shielded Power Inductor

    HCM1305-4R7-R at a glance: molded high-current power inductor, 4.70 uH ±20%, 12 A Irms, Isat 27 A (20% rolloff @ +25 °C), DCR 11 mOhm, 13.8 x 12.5 mm.

    Specification Table

    ParameterValue
    Orderable part numberHCM1305-4R7-R
    OCL (open circuit inductance)4.70 uH ±20%
    FLL minimum, at Isat3.01 uH
    Irms (DC, 40 °C rise)12 A
    Isat (20% rolloff @ +25 °C)27 A
    DCR typical @ +20 °C11 mOhm
    DCR maximum @ +20 °C12.7 mOhm
    K-factor (Bp-p = K x L x dI)161, Bp-p in Gauss
    Package13.8 x 12.5 mm
    Height5.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4371

    Mechanical Dimensions & Pad Layout

    HCM1305-4R7-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4371: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    What the Numbers Mean

    A molded body around an alloy or iron powder core: the winding is pressed into the magnetic material, so the field is contained inside the part and the terminals come straight out of the molding. The result is a shielded inductor with a low profile and a soft saturation curve, on a footprint that is almost all magnetic material.

    The DCR figure of 11 mOhm is what sets the efficiency: at 12 A the winding drops about 0.132 mV and dissipates 1.58 W. On a low-voltage rail that drop is a measurable fraction of the output, so the DCR column deserves as much attention as the inductance.

    Isat is specified as 20% rolloff @ +25 °C, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.

    The core stores roughly 1,713 uJ at the saturation point – a useful figure when sizing the output capacitance that has to absorb the same transient.

    With K = 161, a peak-to-peak ripple of one amp produces roughly 757 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.

    Series Positioning

    The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.

    Within the HCM1305 family this is value 13 of 21, in a range that runs from 0.1 uH to 33 uH.

    Compared with its neighbours in the table, HCM1305-5R6-R trades 3.5 A of rated current for the next inductance step, which is the usual compromise in this family.

    • Core material: iron powder core, 13.8 x 12.5 mm body at 5.0 mm.
    • Typical applications: voltage regulator module (vrm); multi-phase regulators; point-of-load modules; desktop and server vrms and evrds; base station equipment; notebook and laptop regulators.
    • The DCR columns are typical and maximum at +20 °C. Copper rises about 0.4 % per °C, so the hot resistance is higher than either column suggests.

    Sizing and Layout Notes

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 12.7 mOhm becomes roughly 17.9 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.

    • Confirm the shielding is adequate for the adjacent trace routing.
    • Confirm the shielding is adequate for the adjacent trace routing.
    • Build the thermal design on the maximum DCR, not the typical one.

    Frequently Asked Questions

    Is it magnetically shielded?
    Yes. The powder core surrounds the winding, so the leakage field is small and the part can sit close to sensitive traces without a shield can.

    How much inductance is left at rated current?
    That is what the saturation column describes. Isat is the peak current at which inductance has fallen by the stated percentage, so at the rated DC current the part is still inside that boundary.

    Why quote typical and maximum DCR?
    A guaranteed thermal design uses the maximum. A nominal efficiency calculation uses the typical. Publishing both lets the same table serve either purpose.