Eaton HCM1305-7R8-R 7.80 uH Molded Power Inductor, 10 A
Eaton HCM1305-7R8-R 7.80 uH Molded Power Inductor, 10 A

Eaton HCM1305-7R8-R 7.80 uH Molded Power Inductor, 10 A

Share
Eaton HCM1305-7R8-R: molded high-current power inductor, 7.80 uH ±20%, 10 A Irms, Isat 18.5 A, DCR 16.8 mOhm, 13.8 x 12.5 mm.
    • Product Details
    • Download

    Eaton HCM1305-7R8-R 7.80 uH Molded Power Inductor, 10 A

    HCM1305-7R8-R at a glance: molded high-current power inductor, 7.80 uH ±20%, 10 A Irms, Isat 18.5 A (20% rolloff @ +25 °C), DCR 16.8 mOhm, 13.8 x 12.5 mm.

    Ratings at a Glance

    ParameterValue
    Orderable part numberHCM1305-7R8-R
    OCL (open circuit inductance)7.80 uH ±20%
    FLL minimum, at Isat4.99 uH
    Irms (DC, 40 °C rise)10 A
    Isat (20% rolloff @ +25 °C)18.5 A
    DCR typical @ +20 °C16.8 mOhm
    DCR maximum @ +20 °C19.4 mOhm
    K-factor (Bp-p = K x L x dI)117, Bp-p in Gauss
    Package13.8 x 12.5 mm
    Height5.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4371

    Mechanical Dimensions & Pad Layout

    HCM1305-7R8-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4371: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    The Figures Explained

    This is one of the molded power inductors used across VRM, point-of-load and multiphase regulator designs. The family covers a wide inductance range in standard footprints, and every row is characterised for both typical and maximum DCR so the loss budget can be built either way.

    Copper loss at the rated current works out to roughly 1.68 W from a typical DCR of 16.8 mOhm at 10 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.

    Isat is specified as 20% rolloff @ +25 °C, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.

    The core stores roughly 1,335 uJ at the saturation point – a useful figure when sizing the output capacitance that has to absorb the same transient.

    With K = 117, a peak-to-peak ripple of one amp produces roughly 913 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.

    Where This Series Fits

    The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.

    In the HCM1305 line-up this part is number 16 of 21 by inductance, between 0.1 uH and 33 uH.

    One step down the table, HCM1305-6R8-R, sits at 6.80 uH with 11 A and 13 mOhm – the lower inductance buys about 1.5 A of extra current in the same body.

    • Core material: iron powder core, 13.8 x 12.5 mm body at 5.0 mm.
    • Typical applications: voltage regulator module (vrm); multi-phase regulators; point-of-load modules; desktop and server vrms and evrds; base station equipment; notebook and laptop regulators.
    • The DCR columns are typical and maximum at +20 °C. Copper rises about 0.4 % per °C, so the hot resistance is higher than either column suggests.

    Sizing and Layout Notes

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 19.4 mOhm becomes roughly 27.4 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.

    • Verify the body height against the enclosure or heat-spreader clearance.
    • Build the thermal design on the maximum DCR, not the typical one.
    • Build the thermal design on the maximum DCR, not the typical one.

    Frequently Asked Questions

    Can two parts be stacked for higher current?
    Stacking halves the inductance and doubles the current capability in theory, but the two DCRs are not matched and the magnetic coupling is uncontrolled. Use a larger part instead.

    Why quote typical and maximum DCR?
    A guaranteed thermal design uses the maximum. A nominal efficiency calculation uses the typical. Publishing both lets the same table serve either purpose.

    Why quote typical and maximum DCR?
    A guaranteed thermal design uses the maximum. A nominal efficiency calculation uses the typical. Publishing both lets the same table serve either purpose.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products