Eaton HCM1305-R10-R 0.10 uH Shielded Power Inductor
Eaton HCM1305-R10-R 0.10 uH Shielded Power Inductor

Eaton HCM1305-R10-R 0.10 uH Shielded Power Inductor

Share
Eaton HCM1305-R10-R: molded high-current power inductor, 0.10 uH ±20%, 55 A Irms, Isat 118 A, DCR 0.52 mOhm, 13.8 x 12.5 mm.
    • Product Details
    • Download

    Eaton HCM1305-R10-R 0.10 uH Shielded Power Inductor

    HCM1305-R10-R at a glance: molded high-current power inductor, 0.10 uH ±20%, 55 A Irms, Isat 118 A (20% rolloff @ +25 °C), DCR 0.52 mOhm, 13.8 x 12.5 mm.

    Ratings at a Glance

    ParameterValue
    Orderable part numberHCM1305-R10-R
    OCL (open circuit inductance)0.10 uH ±20%
    FLL minimum, at Isat0.064 uH
    Irms (DC, 40 °C rise)55 A
    Isat (20% rolloff @ +25 °C)118 A
    DCR typical @ +20 °C0.52 mOhm
    DCR maximum @ +20 °C0.59 mOhm
    K-factor (Bp-p = K x L x dI)848, Bp-p in Gauss
    Package13.8 x 12.5 mm
    Height5.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4371

    Dimensions and Pad Layout

    HCM1305-R10-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4371: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    What the Numbers Mean

    A molded body around an alloy or iron powder core: the winding is pressed into the magnetic material, so the field is contained inside the part and the terminals come straight out of the molding. The result is a shielded inductor with a low profile and a soft saturation curve, on a footprint that is almost all magnetic material.

    The DCR figure of 0.52 mOhm is what sets the efficiency: at 55 A the winding drops about 0.029 mV and dissipates 1.57 W. On a low-voltage rail that drop is a measurable fraction of the output, so the DCR column deserves as much attention as the inductance.

    The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.

    Energy storage at the saturation current is around 696 uJ, the number that connects the inductance and the current rating into a single transient figure.

    K-factor 848 means the flux swing is about 84.8 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.

    Positioning in the Range

    The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.

    Within the HCM1305 family this is value 1 of 21, in a range that runs from 0.1 uH to 33 uH.

    Compared with its neighbours in the table, HCM1305-R22-R trades 0 A of rated current for the next inductance step, which is the usual compromise in this family.

    • Core material: iron powder core, 13.8 x 12.5 mm body at 5.0 mm.
    • Typical applications: voltage regulator module (vrm); multi-phase regulators; point-of-load modules; desktop and server vrms and evrds; base station equipment; notebook and laptop regulators.
    • The DCR columns are typical and maximum at +20 °C. Copper rises about 0.4 % per °C, so the hot resistance is higher than either column suggests.

    Sizing and Layout Notes

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 0.59 mOhm becomes roughly 0.833 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.

    • Allow for copper drift: resistance rises with temperature at roughly 0.4 % per °C.
    • Check the hot DCR before signing off the efficiency budget.
    • Confirm the peak transient current stays under Isat with tolerance margin.

    Frequently Asked Questions

    How much inductance is left at rated current?
    That is what the saturation column describes. Isat is the peak current at which inductance has fallen by the stated percentage, so at the rated DC current the part is still inside that boundary.

    Can two parts be stacked for higher current?
    Stacking halves the inductance and doubles the current capability in theory, but the two DCRs are not matched and the magnetic coupling is uncontrolled. Use a larger part instead.

    Can two parts be stacked for higher current?
    Stacking halves the inductance and doubles the current capability in theory, but the two DCRs are not matched and the magnetic coupling is uncontrolled. Use a larger part instead.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products