| Parameter | Value |
|---|---|
| Orderable part number | HCM1305-R47-R |
| OCL (open circuit inductance) | 0.47 uH ±20% |
| FLL minimum, at Isat | 0.3 uH |
| Irms (DC, 40 °C rise) | 38 A |
| Isat (20% rolloff @ +25 °C) | 65 A |
| DCR typical @ +20 °C | 0.8 mOhm |
| DCR maximum @ +20 °C | 0.92 mOhm |
| K-factor (Bp-p = K x L x dI) | 506, Bp-p in Gauss |
| Package | 13.8 x 12.5 mm |
| Height | 5.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C (ambient plus self-heating) |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4371 |

Drawing reproduced from Eaton Technical Data 4371: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
This is one of the molded power inductors used across VRM, point-of-load and multiphase regulator designs. The family covers a wide inductance range in standard footprints, and every row is characterised for both typical and maximum DCR so the loss budget can be built either way.
At the rated 38 A the winding dissipates about 1.16 W in copper alone, using the typical DCR of 0.8 mOhm. That figure is the floor of the loss budget: it assumes the current is pure DC, and any ripple adds to it.
Isat is specified as 20% rolloff @ +25 °C, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.
At Isat the part holds about 993 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.
K-factor 506 means the flux swing is about 238 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.
The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.
Of the 21 values listed for HCM1305, this is the 4th, in a family covering 0.1 uH to 33 uH.
The next value up in the same family, HCM1305-R56-R, gives 0.56 uH at 36 A and DCR 1.15 mOhm: the extra inductance costs about 6 A of rated current.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 0.92 mOhm becomes roughly 1.3 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.
What makes a molded inductor different?
The winding is pressed into the magnetic powder with no bobbin or air gap in the path. That is why the body is almost all magnetic material, the DCR is low for the size, and the part is mechanically robust.
What makes a molded inductor different?
The winding is pressed into the magnetic powder with no bobbin or air gap in the path. That is why the body is almost all magnetic material, the DCR is low for the size, and the part is mechanically robust.
Can two parts be stacked for higher current?
Stacking halves the inductance and doubles the current capability in theory, but the two DCRs are not matched and the magnetic coupling is uncontrolled. Use a larger part instead.