Eaton HCM1307-1R0-R: molded high-current power inductor, 1.0 uH ±20%, 29 A Irms, Isat 49 A, DCR 1.7 mOhm, 14.2 x 13 mm.
    • Product Details
    • Download

    Eaton HCM1307-1R0-R 1.0 uH High-Current Inductor 1.7 mOhm

    HCM1307-1R0-R at a glance: molded high-current power inductor, 1.0 uH ±20%, 29 A Irms, Isat 49 A (20% rolloff @ +25 °C), DCR 1.7 mOhm, 14.2 x 13 mm.

    Electrical Specifications

    ParameterValue
    Orderable part numberHCM1307-1R0-R
    OCL (open circuit inductance)1.0 uH ±20%
    FLL minimum, at Isat0.56 uH
    Irms (DC, 40 °C rise)29 A
    Isat (20% rolloff @ +25 °C)49 A
    DCR typical @ +20 °C1.7 mOhm
    DCR maximum @ +20 °C2 mOhm
    K-factor (Bp-p = K x L x dI)111, Bp-p in Gauss
    Package14.2 x 13 mm
    Height6.5 mm
    MountingSurface mount
    Operating temperature-55 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10433

    Dimensions and Pad Layout

    HCM1307-1R0-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10433: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    How to Read These Ratings

    A molded body around an alloy or iron powder core: the winding is pressed into the magnetic material, so the field is contained inside the part and the terminals come straight out of the molding. The result is a shielded inductor with a low profile and a soft saturation curve, on a footprint that is almost all magnetic material.

    With 1.7 mOhm typical, the I-squared-R loss at the full 29 A rating is about 1.43 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.

    Isat is specified as 20% rolloff @ +25 °C, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.

    Energy storage at the saturation current is around 1,200 uJ, the number that connects the inductance and the current rating into a single transient figure.

    The K-factor of 111 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 111 Gauss of Bp-p, the figure the core-loss curve is plotted against.

    Series Positioning

    The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.

    In the HCM1307 line-up this part is number 2 of 3 by inductance, between 0.47 uH and 3.3 uH.

    Compared with its neighbours in the table, HCM1307-3R3-R trades 23 A of rated current for the next inductance step, which is the usual compromise in this family.

    • Core material: iron powder core, 14.2 x 13 mm body at 6.5 mm.
    • Typical applications: multi-phase regulators; voltage regulator modules (vrms); distributed power systems dc-dc converters; desktop and server vrms and evrds; point-of-load (pol) modules; field programmable gate array (fpga) dc-dc converters.
    • The DCR columns are typical and maximum at +20 °C. Copper rises about 0.4 % per °C, so the hot resistance is higher than either column suggests.

    Sizing and Layout Notes

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 2 mOhm becomes roughly 2.83 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.

    • Confirm the shielding is adequate for the adjacent trace routing.
    • Build the thermal design on the maximum DCR, not the typical one.
    • Allow for copper drift: resistance rises with temperature at roughly 0.4 % per °C.

    Frequently Asked Questions

    How much does the inductance drop at rated current?
    That is what the Isat column quantifies. At the rated DC current the part is still inside the rolloff boundary, but the ripple calculation should use the FLL column rather than OCL.

    Can two parts be stacked for higher current?
    Stacking halves the inductance and doubles the current capability in theory, but the two DCRs are not matched and the magnetic coupling is uncontrolled. Use a larger part instead.

    Is it magnetically shielded?
    Yes. The powder core surrounds the winding, so the leakage field is small and the part can sit close to sensitive traces without a shield can.