| Parameter | Value |
|---|---|
| Orderable part number | HCM1707-220-R |
| OCL (open circuit inductance) | 22 uH ±20% |
| FLL minimum, at Isat | 14.1 uH |
| Irms (DC, 40 °C rise) | 9.5 A |
| Isat (20% rolloff @ +25 °C) | 11 A |
| DCR typical @ +20 °C | 21 mOhm |
| DCR maximum @ +20 °C | 23 mOhm |
| K-factor (Bp-p = K x L x dI) | 37, Bp-p in Gauss |
| Package | 17.5 x 17.2 mm |
| Height | 7.0 mm |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C (ambient plus self-heating) |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10295 |

Drawing reproduced from Eaton Technical Data 10295: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
Molded construction is what gives this family its mechanical robustness and its shielding. Because the core surrounds the winding on all sides, the leakage field that would otherwise couple into adjacent traces is small, and the part can be placed close to sensitive nodes.
Copper loss at the rated current works out to roughly 1.9 W from a typical DCR of 21 mOhm at 9.5 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.
The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.
The core stores roughly 1,331 uJ at the saturation point – a useful figure when sizing the output capacitance that has to absorb the same transient.
With K = 37, a peak-to-peak ripple of one amp produces roughly 814 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.
The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.
The HCM1707 family spans 1.5 uH to 68 uH; this row sits at position 8 of 11.
One step down the table, HCM1707-150-R, sits at 15 uH with 12 A and 14.5 mOhm – the lower inductance buys about 3 A of extra current in the same body.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 23 mOhm becomes roughly 32.5 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.
How much inductance is left at rated current?
That is what the saturation column describes. Isat is the peak current at which inductance has fallen by the stated percentage, so at the rated DC current the part is still inside that boundary.
How much does the inductance drop at rated current?
That is what the Isat column quantifies. At the rated DC current the part is still inside the rolloff boundary, but the ripple calculation should use the FLL column rather than OCL.
Why quote typical and maximum DCR?
A guaranteed thermal design uses the maximum. A nominal efficiency calculation uses the typical. Publishing both lets the same table serve either purpose.