Eaton HCM1707-2R2-R: molded high-current power inductor, 2.2 uH ±20%, 37 A Irms, Isat 34 A, DCR 2.15 mOhm, 17.5 x 17.2 mm.
    • Product Details
    • Download

    Eaton HCM1707-2R2-R 2.2 uH Molded Power Inductor, 37 A

    HCM1707-2R2-R at a glance: molded high-current power inductor, 2.2 uH ±20%, 37 A Irms, Isat 34 A (20% rolloff @ +25 °C), DCR 2.15 mOhm, 17.5 x 17.2 mm.

    Electrical Specifications

    ParameterValue
    Orderable part numberHCM1707-2R2-R
    OCL (open circuit inductance)2.2 uH ±20%
    FLL minimum, at Isat1.41 uH
    Irms (DC, 40 °C rise)37 A
    Isat (20% rolloff @ +25 °C)34 A
    DCR typical @ +20 °C2.15 mOhm
    DCR maximum @ +20 °C2.5 mOhm
    K-factor (Bp-p = K x L x dI)103, Bp-p in Gauss
    Package17.5 x 17.2 mm
    Height7.0 mm
    MountingSurface mount
    Operating temperature-40 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10295

    Dimensions and Pad Layout

    HCM1707-2R2-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10295: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    What the Numbers Mean

    A molded body around an alloy or iron powder core: the winding is pressed into the magnetic material, so the field is contained inside the part and the terminals come straight out of the molding. The result is a shielded inductor with a low profile and a soft saturation curve, on a footprint that is almost all magnetic material.

    At the rated 37 A the winding dissipates about 2.94 W in copper alone, using the typical DCR of 2.15 mOhm. That figure is the floor of the loss budget: it assumes the current is pure DC, and any ripple adds to it.

    Isat is specified as 20% rolloff @ +25 °C, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.

    At Isat the part holds about 1,272 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.

    K-factor 103 means the flux swing is about 227 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.

    Where This Series Fits

    The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.

    The HCM1707 family spans 1.5 uH to 68 uH; this row sits at position 2 of 11.

    The next value up in the same family, HCM1707-4R7-R, gives 4.7 uH at 27 A and DCR 4.12 mOhm: the extra inductance costs about 13 A of rated current.

    • Core material: iron powder core, 17.5 x 17.2 mm body at 7.0 mm.
    • Typical applications: voltage regulator module (vrm); multi-phase regulators; point-of-load modules; desktop and server vrms and evrds; data networking and storage systems; base station equipment.
    • The DCR columns are typical and maximum at +20 °C. Copper rises about 0.4 % per °C, so the hot resistance is higher than either column suggests.

    Design Notes

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 2.5 mOhm becomes roughly 3.53 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.

    • Confirm the shielding is adequate for the adjacent trace routing.
    • Allow for copper drift: resistance rises with temperature at roughly 0.4 % per °C.
    • Build the thermal design on the maximum DCR, not the typical one.

    Frequently Asked Questions

    What makes a molded inductor different?
    The winding is pressed into the magnetic powder with no bobbin or air gap in the path. That is why the body is almost all magnetic material, the DCR is low for the size, and the part is mechanically robust.

    What makes a molded inductor different?
    The winding is pressed into the magnetic powder with no bobbin or air gap in the path. That is why the body is almost all magnetic material, the DCR is low for the size, and the part is mechanically robust.

    Can two parts be stacked for higher current?
    Stacking halves the inductance and doubles the current capability in theory, but the two DCRs are not matched and the magnetic coupling is uncontrolled. Use a larger part instead.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products