Eaton HCM1707-470-R 47 uH Molded Power Inductor, 6.8 A
Eaton HCM1707-470-R 47 uH Molded Power Inductor, 6.8 A

Eaton HCM1707-470-R 47 uH Molded Power Inductor, 6.8 A

Share
Eaton HCM1707-470-R: molded high-current power inductor, 47 uH ±20%, 6.8 A Irms, Isat 7.5 A, DCR 41 mOhm, 17.5 x 17.2 mm.
    • Product Details
    • Download

    Eaton HCM1707-470-R 47 uH Molded Power Inductor, 6.8 A

    HCM1707-470-R at a glance: molded high-current power inductor, 47 uH ±20%, 6.8 A Irms, Isat 7.5 A (20% rolloff @ +25 °C), DCR 41 mOhm, 17.5 x 17.2 mm.

    Specification Table

    ParameterValue
    Orderable part numberHCM1707-470-R
    OCL (open circuit inductance)47 uH ±20%
    FLL minimum, at Isat30.1 uH
    Irms (DC, 40 °C rise)6.8 A
    Isat (20% rolloff @ +25 °C)7.5 A
    DCR typical @ +20 °C41 mOhm
    DCR maximum @ +20 °C47 mOhm
    K-factor (Bp-p = K x L x dI)25, Bp-p in Gauss
    Package17.5 x 17.2 mm
    Height7.0 mm
    MountingSurface mount
    Operating temperature-40 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10295

    Mechanical Drawing

    HCM1707-470-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10295: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    Reading the Data Sheet

    This is one of the molded power inductors used across VRM, point-of-load and multiphase regulator designs. The family covers a wide inductance range in standard footprints, and every row is characterised for both typical and maximum DCR so the loss budget can be built either way.

    The DCR figure of 41 mOhm is what sets the efficiency: at 6.8 A the winding drops about 0.279 mV and dissipates 1.9 W. On a low-voltage rail that drop is a measurable fraction of the output, so the DCR column deserves as much attention as the inductance.

    Saturation is quoted as 20% rolloff @ +25 °C. At that point the inductance has fallen to the stated fraction of its nominal value – the part is not damaged there, it simply stops behaving like the inductance on the label. Design the peak current to stay inside that boundary with margin for tolerance.

    Stored energy at Isat is about 1,322 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.

    With K = 25, a peak-to-peak ripple of one amp produces roughly 1,175 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.

    Series Positioning

    The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.

    The HCM1707 family spans 1.5 uH to 68 uH; this row sits at position 10 of 11.

    Compared with its neighbours in the table, HCM1707-680-R trades 3.8 A of rated current for the next inductance step, which is the usual compromise in this family.

    • Core material: iron powder core, 17.5 x 17.2 mm body at 7.0 mm.
    • Typical applications: voltage regulator module (vrm); multi-phase regulators; point-of-load modules; desktop and server vrms and evrds; data networking and storage systems; base station equipment.
    • The DCR columns are typical and maximum at +20 °C. Copper rises about 0.4 % per °C, so the hot resistance is higher than either column suggests.

    Sizing It Into a Design

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 47 mOhm becomes roughly 66.4 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.

    • Confirm the peak transient current stays under Isat with tolerance margin.
    • Confirm the shielding is adequate for the adjacent trace routing.
    • Check the hot DCR before signing off the efficiency budget.

    Frequently Asked Questions

    Is it magnetically shielded?
    Yes. The powder core surrounds the winding, so the leakage field is small and the part can sit close to sensitive traces without a shield can.

    How much inductance is left at rated current?
    That is what the saturation column describes. Isat is the peak current at which inductance has fallen by the stated percentage, so at the rated DC current the part is still inside that boundary.

    Why quote typical and maximum DCR?
    A guaranteed thermal design uses the maximum. A nominal efficiency calculation uses the typical. Publishing both lets the same table serve either purpose.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products