| Parameter | Value |
|---|---|
| Orderable part number | HCM1707-4R7-R |
| OCL (open circuit inductance) | 4.7 uH ±20% |
| FLL minimum, at Isat | 3.01 uH |
| Irms (DC, 40 °C rise) | 27 A |
| Isat (20% rolloff @ +25 °C) | 24 A |
| DCR typical @ +20 °C | 4.12 mOhm |
| DCR maximum @ +20 °C | 4.72 mOhm |
| K-factor (Bp-p = K x L x dI) | 76, Bp-p in Gauss |
| Package | 17.5 x 17.2 mm |
| Height | 7.0 mm |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C (ambient plus self-heating) |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10295 |

Drawing reproduced from Eaton Technical Data 10295: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
The part is a surface-mount molded inductor: powder core, directly wound and pressed, with the terminals formed from the winding ends. The absence of a bobbin or an air gap in the magnetic path is what keeps the DCR low for the current rating, and the soft saturation is a property of the distributed gap.
The DCR figure of 4.12 mOhm is what sets the efficiency: at 27 A the winding drops about 0.111 mV and dissipates 3 W. On a low-voltage rail that drop is a measurable fraction of the output, so the DCR column deserves as much attention as the inductance.
Saturation is quoted as 20% rolloff @ +25 °C. At that point the inductance has fallen to the stated fraction of its nominal value – the part is not damaged there, it simply stops behaving like the inductance on the label. Design the peak current to stay inside that boundary with margin for tolerance.
At Isat the part holds about 1,354 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.
K-factor 76 means the flux swing is about 357 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.
The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.
Of the 11 values listed for HCM1707, this is the 3th, in a family covering 1.5 uH to 68 uH.
The next value up in the same family, HCM1707-6R8-R, gives 6.8 uH at 20 A and DCR 6.55 mOhm: the extra inductance costs about 17 A of rated current.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 4.72 mOhm becomes roughly 6.67 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.
How much does the inductance drop at rated current?
That is what the Isat column quantifies. At the rated DC current the part is still inside the rolloff boundary, but the ripple calculation should use the FLL column rather than OCL.
How much inductance is left at rated current?
That is what the saturation column describes. Isat is the peak current at which inductance has fallen by the stated percentage, so at the rated DC current the part is still inside that boundary.
Can two parts be stacked for higher current?
Stacking halves the inductance and doubles the current capability in theory, but the two DCRs are not matched and the magnetic coupling is uncontrolled. Use a larger part instead.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd