Eaton HCM1A0503V2-2R2-R AEC-Q200 Inductor 2.2 uH, Isat 6.4 A
Eaton HCM1A0503V2-2R2-R AEC-Q200 Inductor 2.2 uH, Isat 6.4 A

Eaton HCM1A0503V2-2R2-R AEC-Q200 Inductor 2.2 uH, Isat 6.4 A

Share
Eaton HCM1A0503V2-2R2-R: AEC-Q200 automotive power inductor, 2.2 uH ±20%, 5.5 A Irms, Isat 6.4 A, DCR 20 mOhm, 5.7 x 5.4 mm.
    • Product Details
    • Download

    Eaton HCM1A0503V2-2R2-R AEC-Q200 Inductor 2.2 uH, Isat 6.4 A

    HCM1A0503V2-2R2-R at a glance: AEC-Q200 automotive power inductor, 2.2 uH ±20%, 5.5 A Irms, Isat 6.4 A (20% rolloff @ +25 °C), DCR 20 mOhm, 5.7 x 5.4 mm.

    Electrical Specifications

    ParameterValue
    Orderable part numberHCM1A0503V2-2R2-R
    OCL (open circuit inductance)2.2 uH ±20%
    FLL minimum, at Isat1.4 uH
    Irms (DC, 40 °C rise)5.5 A
    Isat (20% rolloff @ +25 °C)6.4 A
    DCR typical @ +20 °C20 mOhm
    DCR maximum @ +20 °C23 mOhm
    SRF typical33 MHz
    K-factor (Bp-p = K x L x dI)407, Bp-p in Gauss
    Package5.7 x 5.4 mm
    Height3.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +155 °C (ambient plus self-heating)
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10910

    Outline Drawing

    HCM1A0503V2-2R2-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10910: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    How to Read These Ratings

    AEC-Q200 qualified, molded, magnetically shielded, and rated to +155 °C ambient plus self-heating. The automotive grading is not a label on a commercial part: the test regime covers thermal shock, vibration and moisture, and the data sheet quotes the parameters at the temperature extremes the qualification demands.

    With 20 mOhm typical, the I-squared-R loss at the full 5.5 A rating is about 0.605 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.

    The Isat column is 20% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.

    Energy storage at the saturation current is around 45.1 uJ, the number that connects the inductance and the current rating into a single transient figure.

    K-factor 407 means the flux swing is about 895 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.

    Self-resonant frequency is 33 MHz typical. Above that the part becomes capacitive and stops behaving as an inductor, which is why the switching frequency and its first harmonics should stay well below it.

    Positioning in the Range

    The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.

    Of the 15 values listed for HCM1A0503V2, this is the 10th, in a family covering 0.2 uH to 10 uH.

    Compared with its neighbours in the table, HCM1A0503V2-3R3-R trades 1.5 A of rated current for the next inductance step, which is the usual compromise in this family.

    • Core material: alloy powder core, 5.7 x 5.4 mm body at 3.0 mm.
    • Typical applications: body electronics; central body control module; vehicle access control system; headlamps, tail lamps and interior lighting and led lighting; heating ventilation and air conditioning controllers (hvac); doors, window lift and seat control.
    • The +155 °C rating is ambient plus self-temperature rise. Derate against the hot DCR, not the +20 °C value, when the board sits in a warm enclosure.

    Putting It to Work

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 23 mOhm becomes roughly 35.2 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.

    • Check the hot-corner saturation margin against the worst-case load step.
    • Check Isat and DCR at the hot corner, not at +20 °C.
    • Verify the part marking for revision traceability in production.

    Frequently Asked Questions

    What does AEC-Q200 cover?
    The qualification regime for passive components in automotive use: thermal shock, temperature cycling, vibration, mechanical shock, moisture resistance and solderability, among others. It qualifies the construction, not the board design.

    Why do V2 and V3 parts exist?
    They are later revisions of the same body size with a changed electrical row – typically a higher current rating or an extra parameter such as self-resonant frequency. They are separate orderable parts, not substitutes.

    What is the self-resonant frequency used for?
    It marks the point where the winding capacitance dominates. Keep the switching frequency and the harmonics that carry energy below it, and use it to compare candidates of the same inductance.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products